Emissivity analysis of bulk materials at high temperatures
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23640%2F17%3A43950400" target="_blank" >RIV/49777513:23640/17:43950400 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Emissivity analysis of bulk materials at high temperatures
Popis výsledku v původním jazyce
In this technical report, there are presented analyzed samples, measurement equipments and measurement procedures along with emissivity determination procedures for two emissivity variables - spectral normal emissivity and band effective directional emissivity. The main part of the report is devoted to the emissivity results. The analyzed samples are prepared from the bulk metal and ceramic materials. Except the bulk materials, one coating deposited on the metal substrate and one coating deposited on the ceramic substrate is also analyzed. The spectral normal emissivity should be measured with the increasing sample temperatures from 700 to 980°C, the band effective directional emissivity should be analyzed at temperatures from 700 to 1000°C under the angle of emission from 10° to 80° with step of 10° from the normal of the surface. The spectral normal emissivity is evaluated including uncertainty.
Název v anglickém jazyce
Emissivity analysis of bulk materials at high temperatures
Popis výsledku anglicky
In this technical report, there are presented analyzed samples, measurement equipments and measurement procedures along with emissivity determination procedures for two emissivity variables - spectral normal emissivity and band effective directional emissivity. The main part of the report is devoted to the emissivity results. The analyzed samples are prepared from the bulk metal and ceramic materials. Except the bulk materials, one coating deposited on the metal substrate and one coating deposited on the ceramic substrate is also analyzed. The spectral normal emissivity should be measured with the increasing sample temperatures from 700 to 980°C, the band effective directional emissivity should be analyzed at temperatures from 700 to 1000°C under the angle of emission from 10° to 80° with step of 10° from the normal of the surface. The spectral normal emissivity is evaluated including uncertainty.
Klasifikace
Druh
V<sub>souhrn</sub> - Souhrnná výzkumná zpráva
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
C - Předmět řešení projektu podléhá obchodnímu tajemství (§ 504 Občanského zákoníku), ale název projektu, cíle projektu a u ukončeného nebo zastaveného projektu zhodnocení výsledku řešení projektu (údaje P03, P04, P15, P19, P29, PN8) dodané do CEP, jsou upraveny tak, aby byly zveřejnitelné.
Údaje specifické pro druh výsledku
Počet stran výsledku
41
Místo vydání
—
Název nakladatele resp. objednatele
Ghent University
Verze
—