Quantitative evaluation of active thermography using contrast-to-noise ratio
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23640%2F18%3A43951603" target="_blank" >RIV/49777513:23640/18:43951603 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1364/AO.57.000D49" target="_blank" >http://dx.doi.org/10.1364/AO.57.000D49</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1364/AO.57.000D49" target="_blank" >10.1364/AO.57.000D49</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Quantitative evaluation of active thermography using contrast-to-noise ratio
Popis výsledku v původním jazyce
Active thermography is an infrared based technique for material non-destructive testing. It often uses advanced evaluation techniques based on temperature spatial and temporal changes. Results of the active thermography are contrast differences, which indicate possible defects in an inspected material. These differences cannot be quantified by temperature. This contribution is focused on active thermography results evaluation parameters and contrast to noise ratio (CNR) method, which can be used for quantitative evaluation of the results. Different results interpretation procedures are introduced. An influence of selection method for indication and reference regions and an effect of image scaling on inspection results are discussed
Název v anglickém jazyce
Quantitative evaluation of active thermography using contrast-to-noise ratio
Popis výsledku anglicky
Active thermography is an infrared based technique for material non-destructive testing. It often uses advanced evaluation techniques based on temperature spatial and temporal changes. Results of the active thermography are contrast differences, which indicate possible defects in an inspected material. These differences cannot be quantified by temperature. This contribution is focused on active thermography results evaluation parameters and contrast to noise ratio (CNR) method, which can be used for quantitative evaluation of the results. Different results interpretation procedures are introduced. An influence of selection method for indication and reference regions and an effect of image scaling on inspection results are discussed
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Optics
ISSN
1559-128X
e-ISSN
—
Svazek periodika
57
Číslo periodika v rámci svazku
18
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
"D49"-"D55"
Kód UT WoS článku
000435841800008
EID výsledku v databázi Scopus
2-s2.0-85046270079