A complex four-point method for the evaluation of ohmic and faradaic losses within a redox flow battery single-cell
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23640%2F19%3A43958781" target="_blank" >RIV/49777513:23640/19:43958781 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60461373:22340/19:43920038
Výsledek na webu
<a href="https://doi.org/10.1016/j.mex.2019.03.007" target="_blank" >https://doi.org/10.1016/j.mex.2019.03.007</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.mex.2019.03.007" target="_blank" >10.1016/j.mex.2019.03.007</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A complex four-point method for the evaluation of ohmic and faradaic losses within a redox flow battery single-cell
Popis výsledku v původním jazyce
We propose a complex 4-point method for characterization of flow batteries. The distribution of ohmic and faradaic losses within a single-cell is evaluated from electrochemical impedance spectra and load curves of positive and negative half-cells measured with platinum wire pseudo-reference electrodes positioned in respective electrode compartment. The developed method can be used e.g., for the component screening and in-situ durability studies on single-cell scale. The method was validated on a vanadium redox flow battery single-cell; however, it can be analogically employed for various chemistries of flow battery.
Název v anglickém jazyce
A complex four-point method for the evaluation of ohmic and faradaic losses within a redox flow battery single-cell
Popis výsledku anglicky
We propose a complex 4-point method for characterization of flow batteries. The distribution of ohmic and faradaic losses within a single-cell is evaluated from electrochemical impedance spectra and load curves of positive and negative half-cells measured with platinum wire pseudo-reference electrodes positioned in respective electrode compartment. The developed method can be used e.g., for the component screening and in-situ durability studies on single-cell scale. The method was validated on a vanadium redox flow battery single-cell; however, it can be analogically employed for various chemistries of flow battery.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
10405 - Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1402" target="_blank" >LO1402: CENTEM+</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
MethodsX
ISSN
2215-0161
e-ISSN
—
Svazek periodika
6
Číslo periodika v rámci svazku
2019
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
534-539
Kód UT WoS článku
000493729600062
EID výsledku v databázi Scopus
2-s2.0-85063336766