Quantitative inspection of coating thickness by flash-pulse thermography and time-power transformation evaluation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23640%2F20%3A43958967" target="_blank" >RIV/49777513:23640/20:43958967 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1364/AO.388440" target="_blank" >https://doi.org/10.1364/AO.388440</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1364/AO.388440" target="_blank" >10.1364/AO.388440</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Quantitative inspection of coating thickness by flash-pulse thermography and time-power transformation evaluation
Popis výsledku v původním jazyce
sample. Its application to coatings can indicate a presence of local thickness variations; however, it mostly does not bring any quantitative information about the thickness of the coatings. This contribution is focused on a quantification of the thermographic inspection, which would make possible an evaluation of coating thickness differences. Flash-pulse thermographic testing was applied to thermally sprayed coatings. The importance of a precise synchronization of flash source and thermographic recording was determined. Different evaluation methods were analyzed, and their comparison showed that a time-power transformation method is the most suitable for quantification of the inspection results.
Název v anglickém jazyce
Quantitative inspection of coating thickness by flash-pulse thermography and time-power transformation evaluation
Popis výsledku anglicky
sample. Its application to coatings can indicate a presence of local thickness variations; however, it mostly does not bring any quantitative information about the thickness of the coatings. This contribution is focused on a quantification of the thermographic inspection, which would make possible an evaluation of coating thickness differences. Flash-pulse thermographic testing was applied to thermally sprayed coatings. The importance of a precise synchronization of flash source and thermographic recording was determined. Different evaluation methods were analyzed, and their comparison showed that a time-power transformation method is the most suitable for quantification of the inspection results.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
<a href="/cs/project/EF18_069%2F0010018" target="_blank" >EF18_069/0010018: LABIR-PAV / Předaplikační výzkum infračervených technologií</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Optics
ISSN
1559-128X
e-ISSN
—
Svazek periodika
59
Číslo periodika v rámci svazku
17
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
"E29"-"E35"
Kód UT WoS článku
000540285800006
EID výsledku v databázi Scopus
2-s2.0-85086501201