Vše

Co hledáte?

Vše
Projekty
Výsledky výzkumu
Subjekty

Rychlé hledání

  • Projekty podpořené TA ČR
  • Významné projekty
  • Projekty s nejvyšší státní podporou
  • Aktuálně běžící projekty

Chytré vyhledávání

  • Takto najdu konkrétní +slovo
  • Takto z výsledků -slovo zcela vynechám
  • “Takto můžu najít celou frázi”

Comparison of Six Different Methods for Measuring the Equine Hoof and Recording of its Three-Dimensional Conformation

Identifikátory výsledku

  • Kód výsledku v IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23640%2F23%3A43968950" target="_blank" >RIV/49777513:23640/23:43968950 - isvavai.cz</a>

  • Výsledek na webu

    <a href="https://www.sciencedirect.com/science/article/pii/S0737080622003318" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0737080622003318</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.jevs.2022.104195" target="_blank" >10.1016/j.jevs.2022.104195</a>

Alternativní jazyky

  • Jazyk výsledku

    angličtina

  • Název v původním jazyce

    Comparison of Six Different Methods for Measuring the Equine Hoof and Recording of its Three-Dimensional Conformation

  • Popis výsledku v původním jazyce

    Different measuring techniques have been used to objectify the classification of hoof shape. The MicroScribe is a novel tool that might prove useful for measuring hooves without prior reconstruction or compensation of projection artefacts. The aim of this study was to compare biometric data of the equine hoof collected by the MicroScribe tool and measurements collected directly from hooves, scaled photographs and radiographs, from photogrammetry models and computed tomography datasets. The suitability of MicroScribe generated data to differentiate individual hoof conformations was tested. A total of 62 measures were recorded from 16 forehooves. 21 linear and nine angular measures were collected by at least four methods each, and evaluated further by analysis of variance (ANOVA) and multivariate analysis of variance (MANOVA). Ratios and differences of these measures were calculated as suitable for the definition of hoof shapes and analysed as well. Absolute equivalency of methods was detected for five linear and none of the angular measurements. The precision of the tested measurement methods was comparable. In some cases, different methods measure different structures. Radiographs tended to overestimate, while computed tomography slides to underestimate distances. Photogrammetry and scaled photographs were less suitable for measuring hoof angles. The MicroScribe tool can readily be used for hoof measurements. Its values for linear measures showed good equivalency with other methods based on real hooves. For angular measurements, the uneven hoof surface might introduce imprecision. Not all hoof conformations could be detected based on measuring results alone. Diagnosis by a skilled veterinarian is still essential.

  • Název v anglickém jazyce

    Comparison of Six Different Methods for Measuring the Equine Hoof and Recording of its Three-Dimensional Conformation

  • Popis výsledku anglicky

    Different measuring techniques have been used to objectify the classification of hoof shape. The MicroScribe is a novel tool that might prove useful for measuring hooves without prior reconstruction or compensation of projection artefacts. The aim of this study was to compare biometric data of the equine hoof collected by the MicroScribe tool and measurements collected directly from hooves, scaled photographs and radiographs, from photogrammetry models and computed tomography datasets. The suitability of MicroScribe generated data to differentiate individual hoof conformations was tested. A total of 62 measures were recorded from 16 forehooves. 21 linear and nine angular measures were collected by at least four methods each, and evaluated further by analysis of variance (ANOVA) and multivariate analysis of variance (MANOVA). Ratios and differences of these measures were calculated as suitable for the definition of hoof shapes and analysed as well. Absolute equivalency of methods was detected for five linear and none of the angular measurements. The precision of the tested measurement methods was comparable. In some cases, different methods measure different structures. Radiographs tended to overestimate, while computed tomography slides to underestimate distances. Photogrammetry and scaled photographs were less suitable for measuring hoof angles. The MicroScribe tool can readily be used for hoof measurements. Its values for linear measures showed good equivalency with other methods based on real hooves. For angular measurements, the uneven hoof surface might introduce imprecision. Not all hoof conformations could be detected based on measuring results alone. Diagnosis by a skilled veterinarian is still essential.

Klasifikace

  • Druh

    J<sub>imp</sub> - Článek v periodiku v databázi Web of Science

  • CEP obor

  • OECD FORD obor

    40301 - Veterinary science

Návaznosti výsledku

  • Projekt

  • Návaznosti

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Ostatní

  • Rok uplatnění

    2023

  • Kód důvěrnosti údajů

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Údaje specifické pro druh výsledku

  • Název periodika

    JOURNAL OF EQUINE VETERINARY SCIENCE

  • ISSN

    0737-0806

  • e-ISSN

    1542-7412

  • Svazek periodika

    121

  • Číslo periodika v rámci svazku

    FEB 2023

  • Stát vydavatele periodika

    US - Spojené státy americké

  • Počet stran výsledku

    17

  • Strana od-do

  • Kód UT WoS článku

    000918481400001

  • EID výsledku v databázi Scopus

    2-s2.0-85146009713