Safety and efficacy of catheter ablation on patients with persistent atrial fibrillation by targeting repetitive activation patterns and focal impulses
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60076658%3A12110%2F23%3A43906771" target="_blank" >RIV/60076658:12110/23:43906771 - isvavai.cz</a>
Výsledek na webu
<a href="https://onlinelibrary.wiley.com/doi/10.1111/pace.14708" target="_blank" >https://onlinelibrary.wiley.com/doi/10.1111/pace.14708</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/pace.14708" target="_blank" >10.1111/pace.14708</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Safety and efficacy of catheter ablation on patients with persistent atrial fibrillation by targeting repetitive activation patterns and focal impulses
Popis výsledku v původním jazyce
BackgroundThe study is intended to evaluate the acute and long-term effectiveness and peri-procedural safety in ablation of persistent atrial fibrillation (PsAF) using the CartoFinder algorithm guided ablation (CFGA) targeting on repetitive activation patterns (RAPs) and focal impulses (FIs) identified in dynamic maps. MethodsThis is a prospective, single-arm, multicenter study. A 64-pole multielectrode basket catheter was used for intracardiac global electrogram (EGM) mapping. The RAPs or FIs were repeatedly mapped and ablated for up to five iterations by the CartoFinder algorithm to achieve sinus rhythm (SR) or organized atrial tachycardia (AT), which were followed by PVI. All patients were followed up for 12 months after procedure. ResultsSixty-four PsAF patients (age, 60.7 +/- 9.1 years; male, 76.6%; median PsAF duration, 6.0 months) underwent CFGA on RAPs/FIs. Six patients (9.4%) reported primary adverse event (PAE) including groin hematoma (2), complete heart block (1), tamponade (1), pericarditis (1), and pseudoaneurysm (1). Repeated mapping and ablation on RAPs/FIs resulted in the cycle length (CL) increase from 191.0 +/- 167.6 ms at baseline to 365.7 +/- 296.7 ms in the LA and from 167.8 +/- 41.6 ms to 379.4 +/- 293.5 ms in the RA and 30.2% (19/63) AF termination to SR or organized AT. The 12-month arrhythmia-free and symptomatic AF-free rates were 60.9% and 75.0%, respectively. Patients with acute AF termination showed a higher 12-month arrhythmia-free rate (76.9%) than those without (50.0%, p = .04). ConclusionsThe study demonstrated that the CartoFinder algorithm can be used for global activation mapping during PsAF ablation. Patients with acute AF termination had a lower 12-month AF recurrence rate compared to patients without.
Název v anglickém jazyce
Safety and efficacy of catheter ablation on patients with persistent atrial fibrillation by targeting repetitive activation patterns and focal impulses
Popis výsledku anglicky
BackgroundThe study is intended to evaluate the acute and long-term effectiveness and peri-procedural safety in ablation of persistent atrial fibrillation (PsAF) using the CartoFinder algorithm guided ablation (CFGA) targeting on repetitive activation patterns (RAPs) and focal impulses (FIs) identified in dynamic maps. MethodsThis is a prospective, single-arm, multicenter study. A 64-pole multielectrode basket catheter was used for intracardiac global electrogram (EGM) mapping. The RAPs or FIs were repeatedly mapped and ablated for up to five iterations by the CartoFinder algorithm to achieve sinus rhythm (SR) or organized atrial tachycardia (AT), which were followed by PVI. All patients were followed up for 12 months after procedure. ResultsSixty-four PsAF patients (age, 60.7 +/- 9.1 years; male, 76.6%; median PsAF duration, 6.0 months) underwent CFGA on RAPs/FIs. Six patients (9.4%) reported primary adverse event (PAE) including groin hematoma (2), complete heart block (1), tamponade (1), pericarditis (1), and pseudoaneurysm (1). Repeated mapping and ablation on RAPs/FIs resulted in the cycle length (CL) increase from 191.0 +/- 167.6 ms at baseline to 365.7 +/- 296.7 ms in the LA and from 167.8 +/- 41.6 ms to 379.4 +/- 293.5 ms in the RA and 30.2% (19/63) AF termination to SR or organized AT. The 12-month arrhythmia-free and symptomatic AF-free rates were 60.9% and 75.0%, respectively. Patients with acute AF termination showed a higher 12-month arrhythmia-free rate (76.9%) than those without (50.0%, p = .04). ConclusionsThe study demonstrated that the CartoFinder algorithm can be used for global activation mapping during PsAF ablation. Patients with acute AF termination had a lower 12-month AF recurrence rate compared to patients without.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Pacing and Clinical Electrophysiology
ISSN
0147-8389
e-ISSN
1540-8159
Svazek periodika
46
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
729-737
Kód UT WoS článku
000991474800001
EID výsledku v databázi Scopus
2-s2.0-85159665391