Metody k posouzení rozložitelnosti substrátu při anaerobní digesci a výrobě bioplynu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60076658%3A12220%2F05%3A00005364" target="_blank" >RIV/60076658:12220/05:00005364 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60076658:12220/05:00006137
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Methods to evaluate substrate degradability in anaerobic digestion and biogas production
Popis výsledku v původním jazyce
Two methods developed by prof. Dohányos and doc. Zábranská from ICT in Prague (A) and Oxi Top Control AN12 measuring system manufactured by MERCK Company (B), were used to determine the maximum yield of biogas and methane and the maximum rate of biogas and methane production per unit weight of biomass using buffered and macro- and micro-nutrient enriched grass biomass as a substrate. Statistical evaluation proved that the Oxi Top Control method did not provide significantly lower or higher results thanthe other method that is considered standard. Although the Oxi Top Control AN 12 method has a higher variance of measured values than the standard method, it can be recommended as a project and operation method for its work comfort and expeditiousness.
Název v anglickém jazyce
Methods to evaluate substrate degradability in anaerobic digestion and biogas production
Popis výsledku anglicky
Two methods developed by prof. Dohányos and doc. Zábranská from ICT in Prague (A) and Oxi Top Control AN12 measuring system manufactured by MERCK Company (B), were used to determine the maximum yield of biogas and methane and the maximum rate of biogas and methane production per unit weight of biomass using buffered and macro- and micro-nutrient enriched grass biomass as a substrate. Statistical evaluation proved that the Oxi Top Control method did not provide significantly lower or higher results thanthe other method that is considered standard. Although the Oxi Top Control AN 12 method has a higher variance of measured values than the standard method, it can be recommended as a project and operation method for its work comfort and expeditiousness.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DM - Tuhý odpad a jeho kontrola, recyklace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Plant, Soil and Environment
ISSN
1214-1178
e-ISSN
—
Svazek periodika
51
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
173-178