Image cytometric measurements of diploid, triploid and tetraploid fish erythrocytes in blood smears reflect the true dimensions of live cells
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60076658%3A12310%2F11%3A43873469" target="_blank" >RIV/60076658:12310/11:43873469 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60076658:12520/11:43873469
Výsledek na webu
<a href="http://dx.doi.org/10.1042/CBI20100198" target="_blank" >http://dx.doi.org/10.1042/CBI20100198</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1042/CBI20100198" target="_blank" >10.1042/CBI20100198</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Image cytometric measurements of diploid, triploid and tetraploid fish erythrocytes in blood smears reflect the true dimensions of live cells
Popis výsledku v původním jazyce
Comparative image cytometry of erythrocytes of diploid (2n) and triploid (3n) tench and evolutionary tetraploid (4n) sterlet was performed on whole live unstained cells, live cells with stained nuclei and on stained fixed cells and their nuclei to test if erythrocyte measurements made from blood smears reflect the true dimensions of live cells. Nuclear area and perimeter were the best ploidy level predictors distinguishing accurately among live and fixed 2n, 3n and 4n cells, without significant differences between live and fixed cells within a ploidy level. Redundancy analysis revealed insignificant marginal effect of fixation (explained 2.3 % of variation, F=0.804), the effect of ploidy level was highly significant (explained 50.6 % of variation, F=34.874). Erythrocyte measurements of 2n, 3n and 4n fish erythrocytes and their nuclei from blood smears reflected true dimensions of live cells, and the fixation procedure did not substantially affect their predictive value for ploidy level
Název v anglickém jazyce
Image cytometric measurements of diploid, triploid and tetraploid fish erythrocytes in blood smears reflect the true dimensions of live cells
Popis výsledku anglicky
Comparative image cytometry of erythrocytes of diploid (2n) and triploid (3n) tench and evolutionary tetraploid (4n) sterlet was performed on whole live unstained cells, live cells with stained nuclei and on stained fixed cells and their nuclei to test if erythrocyte measurements made from blood smears reflect the true dimensions of live cells. Nuclear area and perimeter were the best ploidy level predictors distinguishing accurately among live and fixed 2n, 3n and 4n cells, without significant differences between live and fixed cells within a ploidy level. Redundancy analysis revealed insignificant marginal effect of fixation (explained 2.3 % of variation, F=0.804), the effect of ploidy level was highly significant (explained 50.6 % of variation, F=34.874). Erythrocyte measurements of 2n, 3n and 4n fish erythrocytes and their nuclei from blood smears reflected true dimensions of live cells, and the fixation procedure did not substantially affect their predictive value for ploidy level
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EB - Genetika a molekulární biologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Cell Biology International
ISSN
1065-6995
e-ISSN
—
Svazek periodika
35
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
67-71
Kód UT WoS článku
000290283100009
EID výsledku v databázi Scopus
—