High resolution radiography of ambers with pixel detectors
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60076658%3A12310%2F13%3A43885640" target="_blank" >RIV/60076658:12310/13:43885640 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21670/13:00214898 RIV/00064211:_____/13:#0000249 RIV/60077344:_____/13:00434871 RIV/00216208:11110/13:10191295
Výsledek na webu
<a href="http://iopscience.iop.org/1748-0221/8/03/C03024/pdf/1748-0221_8_03_C03024.pdf" target="_blank" >http://iopscience.iop.org/1748-0221/8/03/C03024/pdf/1748-0221_8_03_C03024.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/8/03/C03024" target="_blank" >10.1088/1748-0221/8/03/C03024</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
High resolution radiography of ambers with pixel detectors
Popis výsledku v původním jazyce
Radiography serves as a powerful non-destructive technique for studying inner structure of biological samples and materials. In the last years X-ray imaging has taken advantage of the developments in instrumentation such as table-top micro-focus X-ray tubes and quantum counting pixel detectors. The imaging setups used for our measurements allow for the observation of tiny samples including fossils in amber. The main goal of the study was to apply microradiography as representative of non-destructive andnon-invasive methods for imaging fossils in amber. Those fossils are generally not easy to visualize, especially their internal structures. We investigated a combination of sources and detectors: (a) an X-ray unit for mammography with tungsten anode, emissive spot of 100 mu m and an amorphous selenium imager; (b) a micro-focus X-ray tube with tungsten anode, emissive spot of 5 mu m and a flat panel imager; (c) a nano-focus X-ray tube with tungsten anode, with gauge of emissive spot of 1
Název v anglickém jazyce
High resolution radiography of ambers with pixel detectors
Popis výsledku anglicky
Radiography serves as a powerful non-destructive technique for studying inner structure of biological samples and materials. In the last years X-ray imaging has taken advantage of the developments in instrumentation such as table-top micro-focus X-ray tubes and quantum counting pixel detectors. The imaging setups used for our measurements allow for the observation of tiny samples including fossils in amber. The main goal of the study was to apply microradiography as representative of non-destructive andnon-invasive methods for imaging fossils in amber. Those fossils are generally not easy to visualize, especially their internal structures. We investigated a combination of sources and detectors: (a) an X-ray unit for mammography with tungsten anode, emissive spot of 100 mu m and an amorphous selenium imager; (b) a micro-focus X-ray tube with tungsten anode, emissive spot of 5 mu m and a flat panel imager; (c) a nano-focus X-ray tube with tungsten anode, with gauge of emissive spot of 1
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF INSTRUMENTATION
ISSN
1748-0221
e-ISSN
—
Svazek periodika
8
Číslo periodika v rámci svazku
MAR 2013
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
000316990700024
EID výsledku v databázi Scopus
—