Some notes on surface tension measurements of supercooled water
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60076658%3A12310%2F15%3A43889748" target="_blank" >RIV/60076658:12310/15:43889748 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.epj-conferences.org/articles/epjconf/pdf/2015/11/epjconf_efm2014_02050.pdf" target="_blank" >http://www.epj-conferences.org/articles/epjconf/pdf/2015/11/epjconf_efm2014_02050.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/epjconf/20159202050" target="_blank" >10.1051/epjconf/20159202050</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Some notes on surface tension measurements of supercooled water
Popis výsledku v původním jazyce
The number of methods for the surface tension measurement of liquid in the supercooled state is limited. The capillary elevation method operates with a very small volume of liquid, which enables to measure below the freezing point. The height of the water column in the capillary is growing when the temperature is decreasing. In order to increase the precision of measurement, it is necessary to use a capillary of a very small inner diameter. But the smaller the diameter is, the longer time to reach the steady (stabilized) state of the liquid column in the capillary is necessary. This paper brings a theoretical approach to the velocity of motion of the liquid column in the capillary to the stable position in dependence on the capillary inner diameter. Theoretical results are compared with experimental data with water.
Název v anglickém jazyce
Some notes on surface tension measurements of supercooled water
Popis výsledku anglicky
The number of methods for the surface tension measurement of liquid in the supercooled state is limited. The capillary elevation method operates with a very small volume of liquid, which enables to measure below the freezing point. The height of the water column in the capillary is growing when the temperature is decreasing. In order to increase the precision of measurement, it is necessary to use a capillary of a very small inner diameter. But the smaller the diameter is, the longer time to reach the steady (stabilized) state of the liquid column in the capillary is necessary. This paper brings a theoretical approach to the velocity of motion of the liquid column in the capillary to the stable position in dependence on the capillary inner diameter. Theoretical results are compared with experimental data with water.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BJ - Termodynamika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GP13-20467P" target="_blank" >GP13-20467P: Termodynamické modelování podchlazené vody</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EPJ Web of Conferences
ISBN
—
ISSN
2100-014X
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
EDP Sciences
Místo vydání
Les Ulis Cedex
Místo konání akce
Cesky Krumlov
Datum konání akce
18. 11. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000358249900052