The filtering facepiece respirator increases inspiratory time, but does not change the contribution of breathing compartments during exercise: a randomized trial
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60076658%3A12410%2F24%3A43909748" target="_blank" >RIV/60076658:12410/24:43909748 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.minervamedica.it/en/journals/minerva-respiratory-medicine/article.php?cod=R16Y2025N02A0056" target="_blank" >https://www.minervamedica.it/en/journals/minerva-respiratory-medicine/article.php?cod=R16Y2025N02A0056</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.23736/S2784-8477.25.02191-6" target="_blank" >10.23736/S2784-8477.25.02191-6</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The filtering facepiece respirator increases inspiratory time, but does not change the contribution of breathing compartments during exercise: a randomized trial
Popis výsledku v původním jazyce
BACKGROUND: Facemasks are increasingly widespread after the COVID-19 pandemic. However, there are some concerns regarding potentially harmful effects on respiration. The purpose of this study was to compare breathing patterns and the contribution of individual breathing compartments (IBC) with and without filtering facepiece respirator (FFR) during exercise. METHODS: Twenty-one healthy, well-trained participants (10 female) were randomly selected to complete either a test with FFR or without on the first day, followed by the alternative two days apart. Each day of testing consisted of a graded Bruce protocol on a treadmill (GXT). Three IBC were considered and measured using optoelectronic plethysmography (OEP) during four stages of GXT: pulmonary rib cage (VRCp), abdominal rib cage (VRCa), abdomen (VAb). Concurrently, inspiratory time (Ti), expiratory time (TE) and respiratory frequency (fR) were collected. RESULTS: Despite a substantial increase in inspiratory mean time during GXT stage 2 (13.2%, d=0.41), stage 3 (10.7%, d=0.41), and stage 4 (11.5%, d=0.67) while wearing FFR, the relative contributions of IBCs did not differ between conditions. CONCLUSIONS: This suggests that the increased work of breathing due to the respirator resistance is evenly distributed among the IBCs. While there may be negligible acute effects of FFR on breathing in well-trained individuals, long-term effects may differ. (Cite this article as: Marko D, Harbour E, Bahensk & yacute; P, Krajcigr M, Mal & aacute;tov & aacute; R, Mal & yacute; T, et al. The filtering facepiece respirator increases inspiratory time, but does not change the contribution of breathing compartments during exercise: a randomized trial. Minerva Respir Med 2025;64:56-63. DOI: 10.23736/S2784-8477.25.02191-6)
Název v anglickém jazyce
The filtering facepiece respirator increases inspiratory time, but does not change the contribution of breathing compartments during exercise: a randomized trial
Popis výsledku anglicky
BACKGROUND: Facemasks are increasingly widespread after the COVID-19 pandemic. However, there are some concerns regarding potentially harmful effects on respiration. The purpose of this study was to compare breathing patterns and the contribution of individual breathing compartments (IBC) with and without filtering facepiece respirator (FFR) during exercise. METHODS: Twenty-one healthy, well-trained participants (10 female) were randomly selected to complete either a test with FFR or without on the first day, followed by the alternative two days apart. Each day of testing consisted of a graded Bruce protocol on a treadmill (GXT). Three IBC were considered and measured using optoelectronic plethysmography (OEP) during four stages of GXT: pulmonary rib cage (VRCp), abdominal rib cage (VRCa), abdomen (VAb). Concurrently, inspiratory time (Ti), expiratory time (TE) and respiratory frequency (fR) were collected. RESULTS: Despite a substantial increase in inspiratory mean time during GXT stage 2 (13.2%, d=0.41), stage 3 (10.7%, d=0.41), and stage 4 (11.5%, d=0.67) while wearing FFR, the relative contributions of IBCs did not differ between conditions. CONCLUSIONS: This suggests that the increased work of breathing due to the respirator resistance is evenly distributed among the IBCs. While there may be negligible acute effects of FFR on breathing in well-trained individuals, long-term effects may differ. (Cite this article as: Marko D, Harbour E, Bahensk & yacute; P, Krajcigr M, Mal & aacute;tov & aacute; R, Mal & yacute; T, et al. The filtering facepiece respirator increases inspiratory time, but does not change the contribution of breathing compartments during exercise: a randomized trial. Minerva Respir Med 2025;64:56-63. DOI: 10.23736/S2784-8477.25.02191-6)
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30203 - Respiratory systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Minerva Respiratory Medicine
ISSN
2784-8477
e-ISSN
2724-6493
Svazek periodika
64
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
IT - Italská republika
Počet stran výsledku
8
Strana od-do
56-63
Kód UT WoS článku
001529087800002
EID výsledku v databázi Scopus
—