Unsupervised Adaptive Filter for Baseline Thresholding and Elimination in Liquid Chromatography-Mass Spectrometry via Approximation of the Standard Deviation of Baseline Distribution in Retention Time Domain
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60076658%3A12520%2F13%3A43885199" target="_blank" >RIV/60076658:12520/13:43885199 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.akademiai.com/content/w371212023q78740/?genre=article&id=doi%3a10.1556%2fAChrom.25.2013.2.4" target="_blank" >http://www.akademiai.com/content/w371212023q78740/?genre=article&id=doi%3a10.1556%2fAChrom.25.2013.2.4</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1556/AChrom.25.2013.2.4" target="_blank" >10.1556/AChrom.25.2013.2.4</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Unsupervised Adaptive Filter for Baseline Thresholding and Elimination in Liquid Chromatography-Mass Spectrometry via Approximation of the Standard Deviation of Baseline Distribution in Retention Time Domain
Popis výsledku v původním jazyce
The omitting presence of a baseline (background, systemic noise, mobile phase) in liquid chromatography-mass spectrometry (LC-MS) measurements impedes objective analysis. Therefore, there is a demand to remove its contribution from the signal response. Elimination of baseline contribution is justified by increasing the data mining output, both qualitatively and quantitatively. Behavior of the baseline content is not perfectly constant on the time axis, and it is often necessary to experiment with gradient changes. However, the behavior could be parametrized using a technique derived from statistical moments. In this article, we propose adaptive thresholding as an unsupervised method for baseline removal from the measurement data. Results of a real analyte measurement are discussed to illustrate its efficiency.
Název v anglickém jazyce
Unsupervised Adaptive Filter for Baseline Thresholding and Elimination in Liquid Chromatography-Mass Spectrometry via Approximation of the Standard Deviation of Baseline Distribution in Retention Time Domain
Popis výsledku anglicky
The omitting presence of a baseline (background, systemic noise, mobile phase) in liquid chromatography-mass spectrometry (LC-MS) measurements impedes objective analysis. Therefore, there is a demand to remove its contribution from the signal response. Elimination of baseline contribution is justified by increasing the data mining output, both qualitatively and quantitatively. Behavior of the baseline content is not perfectly constant on the time axis, and it is often necessary to experiment with gradient changes. However, the behavior could be parametrized using a technique derived from statistical moments. In this article, we propose adaptive thresholding as an unsupervised method for baseline removal from the measurement data. Results of a real analyte measurement are discussed to illustrate its efficiency.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F01.0024" target="_blank" >ED2.1.00/01.0024: Jihočeské výzkumné centrum akvakultury a biodiverzity hydrocenóz</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
ACTA CHROMATOGRAPHICA
ISSN
1233-2356
e-ISSN
—
Svazek periodika
25
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
HU - Maďarsko
Počet stran výsledku
17
Strana od-do
257-273
Kód UT WoS článku
000319748700004
EID výsledku v databázi Scopus
—