Storage effect on the analysis of pharmaceuticals and personal care products in wastewater
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60076658%3A12520%2F14%3A43886863" target="_blank" >RIV/60076658:12520/14:43886863 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S0045653514003361" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0045653514003361</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chemosphere.2014.02.067" target="_blank" >10.1016/j.chemosphere.2014.02.067</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Storage effect on the analysis of pharmaceuticals and personal care products in wastewater
Popis výsledku v původním jazyce
In this study, the stability of 124 target analytes in influent and effluent wastewater samples during short-term (4 degrees C) and long-term (-18 degrees C) storage was assessed. The most common storage scenario was considered, in which samples were frozen immediately after sampling without any pre-treatment. During short-term storage more analytes remained stable (concentration during storage was in the range of 60-120% of the initial concentration) at 4 degrees C than at -18 degrees C. During long-term storage (-18 degrees C), three types of behavior were observed: constant concentrations throughout the experimental period, decreasing concentrations with time, and loss of the compound from the sample after freezing. Differences between effluent andinfluent samples were observed for 50 out of 124 tested PPCPs. The amount of stable analytes decreased with time during long-term storage. 72% and 56% of the target compounds in the effluent and influent wastewater, respectively, remained
Název v anglickém jazyce
Storage effect on the analysis of pharmaceuticals and personal care products in wastewater
Popis výsledku anglicky
In this study, the stability of 124 target analytes in influent and effluent wastewater samples during short-term (4 degrees C) and long-term (-18 degrees C) storage was assessed. The most common storage scenario was considered, in which samples were frozen immediately after sampling without any pre-treatment. During short-term storage more analytes remained stable (concentration during storage was in the range of 60-120% of the initial concentration) at 4 degrees C than at -18 degrees C. During long-term storage (-18 degrees C), three types of behavior were observed: constant concentrations throughout the experimental period, decreasing concentrations with time, and loss of the compound from the sample after freezing. Differences between effluent andinfluent samples were observed for 50 out of 124 tested PPCPs. The amount of stable analytes decreased with time during long-term storage. 72% and 56% of the target compounds in the effluent and influent wastewater, respectively, remained
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DJ - Znečištění a kontrola vody
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemosphere
ISSN
0045-6535
e-ISSN
—
Svazek periodika
111
Číslo periodika v rámci svazku
Neuveden
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
55-60
Kód UT WoS článku
000339601600009