Metals and their alloys are often used in the production of implants or stents, and are applied to a living organism. For this application it is necessary to provide for biocompatibility, i.e. determine the likely response of the organism to the embeddedmetal material. Reactions of cell populations in vitro or ex vivo are primary biocompatibility tests. Determination of cytotoxicity is inefficient for these purposes; it is necessary to find out the degree of tolerance of the cell population to the implanted metallic material before the subsequent tests are conducted on experimental animals. Special test trials in patients with allergy to some of the components of the selected alloy are the peak of the pyramid. In the statement we deal with reaction ofanimal cell lines to certain metals and alloys used in medicine that are examined in the system of time lapse cinephotomicrography of live cell populations in vitro. Cell lines are scanned in the direct contact with a metal, possibly met
Název v anglickém jazyce
Biocompatibility of metals and their surfaces
Popis výsledku anglicky
Metals and their alloys are often used in the production of implants or stents, and are applied to a living organism. For this application it is necessary to provide for biocompatibility, i.e. determine the likely response of the organism to the embeddedmetal material. Reactions of cell populations in vitro or ex vivo are primary biocompatibility tests. Determination of cytotoxicity is inefficient for these purposes; it is necessary to find out the degree of tolerance of the cell population to the implanted metallic material before the subsequent tests are conducted on experimental animals. Special test trials in patients with allergy to some of the components of the selected alloy are the peak of the pyramid. In the statement we deal with reaction ofanimal cell lines to certain metals and alloys used in medicine that are examined in the system of time lapse cinephotomicrography of live cell populations in vitro. Cell lines are scanned in the direct contact with a metal, possibly met
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JC - Počítačový hardware a software
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
24th International Conference on Metallurgy and Materials, Conference Proceedings - METAL 2015
ISBN
978-80-87294-62-8
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
964-969
Název nakladatele
Tanger Ltd.
Místo vydání
Ostrava
Místo konání akce
Brno, Czech Republic
Datum konání akce
3. 6. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce