Magnetically responsive textile for a new preconcentration procedure: Magnetic textile solid phase extraction
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60077344%3A_____%2F18%3A00493307" target="_blank" >RIV/60077344:_____/18:00493307 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989592:15310/18:73588126
Výsledek na webu
<a href="http://dx.doi.org/10.1177/1528083717740767" target="_blank" >http://dx.doi.org/10.1177/1528083717740767</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1177/1528083717740767" target="_blank" >10.1177/1528083717740767</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Magnetically responsive textile for a new preconcentration procedure: Magnetic textile solid phase extraction
Popis výsledku v původním jazyce
A new preconcentration procedure named ‘‘Magnetic textile solid phase extraction’’ was developed. A piece of nonwoven textile (fabric) was used for the immobilization of copper phthalocyanine dye and employed for the adsorption of crystal violet and safranin O from large volumes of sample. The bound dye was eluted into small volume of methanol. The limit of detection and limit of quantification values for safranin O were 2.66 µg/L and 8.87 µg/L, while for crystal violet these values were 2.17 µg/L and 7.23 µg/L, respectively. Linearity in the range 5–100 µg/L was observed. In order to prepare magnetically responsive adsorbent, an iron-based standard staple was inserted in the textile material using an office stapler. The developed procedure can be easily adapted for the detection of large variety of analytes in biochemistry, biotechnology, environmental technology, and forensic analysis.
Název v anglickém jazyce
Magnetically responsive textile for a new preconcentration procedure: Magnetic textile solid phase extraction
Popis výsledku anglicky
A new preconcentration procedure named ‘‘Magnetic textile solid phase extraction’’ was developed. A piece of nonwoven textile (fabric) was used for the immobilization of copper phthalocyanine dye and employed for the adsorption of crystal violet and safranin O from large volumes of sample. The bound dye was eluted into small volume of methanol. The limit of detection and limit of quantification values for safranin O were 2.66 µg/L and 8.87 µg/L, while for crystal violet these values were 2.17 µg/L and 7.23 µg/L, respectively. Linearity in the range 5–100 µg/L was observed. In order to prepare magnetically responsive adsorbent, an iron-based standard staple was inserted in the textile material using an office stapler. The developed procedure can be easily adapted for the detection of large variety of analytes in biochemistry, biotechnology, environmental technology, and forensic analysis.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Industrial Textiles
ISSN
1528-0837
e-ISSN
—
Svazek periodika
48
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
11
Strana od-do
761-771
Kód UT WoS článku
000444085400004
EID výsledku v databázi Scopus
2-s2.0-85042224210