Biosensor for rapid detection of SARS-CoV-2 in real-world samples
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60077344%3A_____%2F21%3A00558950" target="_blank" >RIV/60077344:_____/21:00558950 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68378271:_____/21:00558950 RIV/60076658:12310/21:43906082
Výsledek na webu
<a href="http://dx.doi.org/10.1109/SENSORS47087.2021.9639783" target="_blank" >http://dx.doi.org/10.1109/SENSORS47087.2021.9639783</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/SENSORS47087.2021.9639783" target="_blank" >10.1109/SENSORS47087.2021.9639783</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Biosensor for rapid detection of SARS-CoV-2 in real-world samples
Popis výsledku v původním jazyce
The current COVID-19 pandemic has become a worldwide problem with more than 169 million people infected by May 2021. Here we demonstrate a unique technology, based on the quartz crystal microbalance method, for the rapid detection of SARS-CoV-2. This biosensor fulfils all of the many requirements for the rapid detection of SARS-CoV-2 in complex samples. This is achieved by a tailored antifouling surface post-modified with antibodies against SARS-CoV-2 nucleocapsid protein (N). The A-QCM profits from absence of sample pre-treatment and utilizes the natural properties of N protein, which forms complexes with vRNA. Thanks to this, the clinically relevant LOD of 6.7×103 PFU/mL was reached using one-step detection assay. The A-QCM biosensor was also validated with clinical samples (i.e. nasopharyngeal swabs) with full agreement with qRT-PCR.
Název v anglickém jazyce
Biosensor for rapid detection of SARS-CoV-2 in real-world samples
Popis výsledku anglicky
The current COVID-19 pandemic has become a worldwide problem with more than 169 million people infected by May 2021. Here we demonstrate a unique technology, based on the quartz crystal microbalance method, for the rapid detection of SARS-CoV-2. This biosensor fulfils all of the many requirements for the rapid detection of SARS-CoV-2 in complex samples. This is achieved by a tailored antifouling surface post-modified with antibodies against SARS-CoV-2 nucleocapsid protein (N). The A-QCM profits from absence of sample pre-treatment and utilizes the natural properties of N protein, which forms complexes with vRNA. Thanks to this, the clinically relevant LOD of 6.7×103 PFU/mL was reached using one-step detection assay. The A-QCM biosensor was also validated with clinical samples (i.e. nasopharyngeal swabs) with full agreement with qRT-PCR.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10610 - Biophysics
Návaznosti výsledku
Projekt
<a href="/cs/project/GA21-19779S" target="_blank" >GA21-19779S: Pokročilé ultra-rezistentní funkční polymerní kartáče v komplexních biologických médiích</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IEEE SENSORS 2021
ISBN
978-1-7281-9501-8
ISSN
1930-0395
e-ISSN
—
Počet stran výsledku
4
Strana od-do
(2021)
Název nakladatele
IEEE
Místo vydání
New York
Místo konání akce
Sydney
Datum konání akce
31. 10. 2021
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000755468300249