Measurement of biological aerosols in an aerosol chamber
Popis výsledku v původním jazyce
The standard system for aerosol exposure of mice in aerosol chamber was evolved. This system will be used for the immunological studies of murine organism after aerosol exposure of intracellular pathogens - Francisella tularensis model. The pneumatic nebulizer with recycling of bacterial suspension, dynamic aerosol chamber "nose only" for exposure of 12 mice were applied. Pressure on orifice and flow rate through the atomizer, flow rate, temperature and humidity in the chamber were measured. Density, viscosity, consumption of aerosolized suspension and number of cultivable bacteria in suspension were appointed. CMD (count median diameter), MMD (mass median diameter) and GSD (geometric standard deviation) were determined by the 4-stage cascade impactoraccording May (1). The number of cultivable F. tularensis in aerosol was established by the glass impinger and Andersen 6-stage cascade impactor (2). The correlation between technical parameters, MMD, GSD and number of cultivable bacteria
Název v anglickém jazyce
Measurement of biological aerosols in an aerosol chamber
Popis výsledku anglicky
The standard system for aerosol exposure of mice in aerosol chamber was evolved. This system will be used for the immunological studies of murine organism after aerosol exposure of intracellular pathogens - Francisella tularensis model. The pneumatic nebulizer with recycling of bacterial suspension, dynamic aerosol chamber "nose only" for exposure of 12 mice were applied. Pressure on orifice and flow rate through the atomizer, flow rate, temperature and humidity in the chamber were measured. Density, viscosity, consumption of aerosolized suspension and number of cultivable bacteria in suspension were appointed. CMD (count median diameter), MMD (mass median diameter) and GSD (geometric standard deviation) were determined by the 4-stage cascade impactoraccording May (1). The number of cultivable F. tularensis in aerosol was established by the glass impinger and Andersen 6-stage cascade impactor (2). The correlation between technical parameters, MMD, GSD and number of cultivable bacteria
Klasifikace
Druh
C - Kapitola v odborné knize
CEP obor
EC - Imunologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2000
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název knihy nebo sborníku
Rapid methods for analysis of biological materials in the environment
ISBN
0-7923-6304-3
Počet stran výsledku
16
Strana od-do
—
Počet stran knihy
—
Název nakladatele
Kluwer Academic Publishers
Místo vydání
Dordrecht