Measuring alpha and beta activity of filter and swab samples with LSC
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG42__%2F10%3A00428128" target="_blank" >RIV/60162694:G42__/10:00428128 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measuring alpha and beta activity of filter and swab samples with LSC
Popis výsledku v původním jazyce
Analysis of alpha and beta emitters in aerosol filters and swabs of different materials by liquid scintillation counter is discussed. This method appears suitable for fast determination of activity of radionuclides due to direct alpha and beta separation, measurement in 4? geometry and without sample treatment. The selected group of radionuclides was chosen with respect to military significance, radiotoxicity, and possibility of potential misuse. 90Sr and 239Pu were selected as model radionuclides. Three types of filters were examined, and the attention was also focused on optimizing the type and volume of LSC cocktail. The efficiencies for 239Pu and 90Sr were 90 % and 79 %, respectively. This method was the most effective for the glass fiber filters measured with the MaxiLight cocktail.
Název v anglickém jazyce
Measuring alpha and beta activity of filter and swab samples with LSC
Popis výsledku anglicky
Analysis of alpha and beta emitters in aerosol filters and swabs of different materials by liquid scintillation counter is discussed. This method appears suitable for fast determination of activity of radionuclides due to direct alpha and beta separation, measurement in 4? geometry and without sample treatment. The selected group of radionuclides was chosen with respect to military significance, radiotoxicity, and possibility of potential misuse. 90Sr and 239Pu were selected as model radionuclides. Three types of filters were examined, and the attention was also focused on optimizing the type and volume of LSC cocktail. The efficiencies for 239Pu and 90Sr were 90 % and 79 %, respectively. This method was the most effective for the glass fiber filters measured with the MaxiLight cocktail.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CH - Jaderná a kvantová chemie, fotochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Radioanalytical and Nuclear Chemistry
ISSN
0236-5731
e-ISSN
—
Svazek periodika
286
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
HU - Maďarsko
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
000285112200035
EID výsledku v databázi Scopus
—