Photo-induced flow-injection determination of nitrate in water
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG42__%2F14%3A00521103" target="_blank" >RIV/60162694:G42__/14:00521103 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68081715:_____/14:00430878
Výsledek na webu
<a href="http://vavtest.unob.cz/registr" target="_blank" >http://vavtest.unob.cz/registr</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Photo-induced flow-injection determination of nitrate in water
Popis výsledku v původním jazyce
A sensitive flow-injection method for the chemiluminescent determination of ultra-low concentration of nitrate in water is presented. Nitrate is on-line photolytically converted to peroxynitrite by absorption of UV light inside of 60 mm long quartz capillary (i.d. 530 ?m, o.d. 720 ?m). Peroxynitrite is subsequently determined by the chemiluminescent reaction with luminol. The detection limit of nitrate is 7 x 10-10 M (S/N = 3). The linear range of the method is 2 x 10-9?1 x 10-5 M nitrate. The interference of nitrite is eliminated by its conversion to nitrogen after mixing of sample with a solution of sulfamidic acid. Other common anions do not interfere. The interference of cations is eliminated by passing the sample through a cation-exchange column.The FIA procedure allows analysing of 15 samples per hour. The method was applied to the determination of nitrate in various real water samples. The results are in good agreement with a reference ion chromatographic method.
Název v anglickém jazyce
Photo-induced flow-injection determination of nitrate in water
Popis výsledku anglicky
A sensitive flow-injection method for the chemiluminescent determination of ultra-low concentration of nitrate in water is presented. Nitrate is on-line photolytically converted to peroxynitrite by absorption of UV light inside of 60 mm long quartz capillary (i.d. 530 ?m, o.d. 720 ?m). Peroxynitrite is subsequently determined by the chemiluminescent reaction with luminol. The detection limit of nitrate is 7 x 10-10 M (S/N = 3). The linear range of the method is 2 x 10-9?1 x 10-5 M nitrate. The interference of nitrite is eliminated by its conversion to nitrogen after mixing of sample with a solution of sulfamidic acid. Other common anions do not interfere. The interference of cations is eliminated by passing the sample through a cation-exchange column.The FIA procedure allows analysing of 15 samples per hour. The method was applied to the determination of nitrate in various real water samples. The results are in good agreement with a reference ion chromatographic method.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/OVUOFEM200904" target="_blank" >OVUOFEM200904: PRINCIP - Analyzátor výbušnin na mikrofluidním principu pro polní podmínky</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Environmental Analytical Chemistry
ISSN
0306-7319
e-ISSN
—
Svazek periodika
94
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
12
Strana od-do
1038-1049
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—