The Temperature Effect of Photovoltaic Systems with dc-dc Converters
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG43__%2F09%3A%230003118" target="_blank" >RIV/60162694:G43__/09:#0003118 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60162694:G43__/09:#0003286
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Temperature Effect of Photovoltaic Systems with dc-dc Converters
Popis výsledku v původním jazyce
This paper describes the temperature effect of photovoltaic modules and the mathematical modeling due to Matlab-Simulink. The temperature has effect to reduction of total efficiency which cannot be overlooked. Paper shows the application of maximum powertracker techniques (MPT) to achieve of decreasing of temperature effect to get the maximum power of photovoltaic cells. The maximum power tracker one of the major trends in photovoltaic technology towards system modular design based on the optimum powercontrol with low cost and optimal energy yield. The algorithms of MPT are shown in the paper and it is discussed. The results of modeling of the temperature analyses are verified by experimental measurements on the photovoltaic set up.
Název v anglickém jazyce
The Temperature Effect of Photovoltaic Systems with dc-dc Converters
Popis výsledku anglicky
This paper describes the temperature effect of photovoltaic modules and the mathematical modeling due to Matlab-Simulink. The temperature has effect to reduction of total efficiency which cannot be overlooked. Paper shows the application of maximum powertracker techniques (MPT) to achieve of decreasing of temperature effect to get the maximum power of photovoltaic cells. The maximum power tracker one of the major trends in photovoltaic technology towards system modular design based on the optimum powercontrol with low cost and optimal energy yield. The algorithms of MPT are shown in the paper and it is discussed. The results of modeling of the temperature analyses are verified by experimental measurements on the photovoltaic set up.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F09%2F0013" target="_blank" >GA102/09/0013: Bi-direkcionální DC-DC měniče fotovoltaických systémů s využitím sledovače maximálního výkonu</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the Recent Advances in Mechatronics 2008-2009
ISBN
978-3-642-05021-3
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
Springer - Veralag Berlin Heidelberg Press
Místo vydání
Německo
Místo konání akce
Luhačovice, ČR
Datum konání akce
1. 1. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—