Photovoltaic Model for Circuit Simulation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG43__%2F12%3A00481053" target="_blank" >RIV/60162694:G43__/12:00481053 - isvavai.cz</a>
Výsledek na webu
<a href="http://vavtest.unob.cz/registr" target="_blank" >http://vavtest.unob.cz/registr</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Photovoltaic Model for Circuit Simulation
Popis výsledku v původním jazyce
This paper looks at the performance of model of photovoltaic modules. This paper presents the photovoltaic panel model obtained by the identification method on the basis of measured data. The obtained model is applied in an analog-digital simulator thatprovides an simulations as a functional circuit model with numerical algorithms. The constructed model results from the nonlinear form of Norton model and is further used for the model performance optimization. This approach can be has its advantages, which are discussed in paper. The final model regards the solar radiation and is valid for a particular panel and temperature changes. The final constructed model is experimentally tested both on the level of simulation and the real measurements. The article also contains the analysis of implemented PV panel model errors. These results can be useful in designing of photovoltaic systems with maximum power point tracking.
Název v anglickém jazyce
Photovoltaic Model for Circuit Simulation
Popis výsledku anglicky
This paper looks at the performance of model of photovoltaic modules. This paper presents the photovoltaic panel model obtained by the identification method on the basis of measured data. The obtained model is applied in an analog-digital simulator thatprovides an simulations as a functional circuit model with numerical algorithms. The constructed model results from the nonlinear form of Norton model and is further used for the model performance optimization. This approach can be has its advantages, which are discussed in paper. The final model regards the solar radiation and is valid for a particular panel and temperature changes. The final constructed model is experimentally tested both on the level of simulation and the real measurements. The article also contains the analysis of implemented PV panel model errors. These results can be useful in designing of photovoltaic systems with maximum power point tracking.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
KA - Vojenství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F09%2F0013" target="_blank" >GA102/09/0013: Bi-direkcionální DC-DC měniče fotovoltaických systémů s využitím sledovače maximálního výkonu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society
ISBN
978-1-4673-2420-5
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
1-7
Název nakladatele
IEEE Industrial Electronics Society
Místo vydání
Montreal, Canada
Místo konání akce
Montreal, Canada
Datum konání akce
1. 1. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce