The Changes of Surface Texture Parameters of the Duplex Systems: Nitrided Layer - Coating at CoCrMo Alloy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG43__%2F14%3A00536615" target="_blank" >RIV/60162694:G43__/14:00536615 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60162694:G43__/14:00520845
Výsledek na webu
<a href="http://ecst.ecsdl.org/content/63/1" target="_blank" >http://ecst.ecsdl.org/content/63/1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1149/06301.0255ecst" target="_blank" >10.1149/06301.0255ecst</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Changes of Surface Texture Parameters of the Duplex Systems: Nitrided Layer - Coating at CoCrMo Alloy
Popis výsledku v původním jazyce
CoCrMo alloys have been used for biomedical implants for a number of years. One of the important parameters which influences durability of the coating and thus whole implant are parameters of surface texture, namely Ra and Rt, which are determined by standards ISO 7206-2:2011 and ISO 7207-2:2011. Three duplex surface systems were applied to improve mechanical properties. The combination of plasma nitriding and subsequent deposited thin films of the nACo3®, DLC and ZrN were used as a duplex treatment. Plasma nitriding was implemented under these conditions: duration time 10 hours, the ratio of gases H2:N2=3:1, process temperature 450 °C, 500 °C and 550 °C. The surface texture parameters were measured on the polished surface of the CoCrMo alloy at first, then on the polished surface after plasma nitridation process and finally on the polished surface of deposited coating. It has been demonstrated that deposition of the selected coatings on the nitride surface influences the surface texture parameters Ra and Rt.
Název v anglickém jazyce
The Changes of Surface Texture Parameters of the Duplex Systems: Nitrided Layer - Coating at CoCrMo Alloy
Popis výsledku anglicky
CoCrMo alloys have been used for biomedical implants for a number of years. One of the important parameters which influences durability of the coating and thus whole implant are parameters of surface texture, namely Ra and Rt, which are determined by standards ISO 7206-2:2011 and ISO 7207-2:2011. Three duplex surface systems were applied to improve mechanical properties. The combination of plasma nitriding and subsequent deposited thin films of the nACo3®, DLC and ZrN were used as a duplex treatment. Plasma nitriding was implemented under these conditions: duration time 10 hours, the ratio of gases H2:N2=3:1, process temperature 450 °C, 500 °C and 550 °C. The surface texture parameters were measured on the polished surface of the CoCrMo alloy at first, then on the polished surface after plasma nitridation process and finally on the polished surface of deposited coating. It has been demonstrated that deposition of the selected coatings on the nitride surface influences the surface texture parameters Ra and Rt.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
ECS Transactions
ISBN
—
ISSN
1938-5862
e-ISSN
—
Počet stran výsledku
5
Strana od-do
255-259
Název nakladatele
The Electrochemical Society
Místo vydání
Spojené státy americké
Místo konání akce
Spojené státy americké
Datum konání akce
1. 1. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—