Experimental Ballistic Loading of Steel Fiber Reinforced Concrete Slabs and Unreinforced Concrete Slabs by Plastic Explosives
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG43__%2F17%3A00534110" target="_blank" >RIV/60162694:G43__/17:00534110 - isvavai.cz</a>
Výsledek na webu
<a href="http://link.springer.com/chapter/10.1007/978-981-10-3247-9_13" target="_blank" >http://link.springer.com/chapter/10.1007/978-981-10-3247-9_13</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-981-10-3247-9_13" target="_blank" >10.1007/978-981-10-3247-9_13</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Experimental Ballistic Loading of Steel Fiber Reinforced Concrete Slabs and Unreinforced Concrete Slabs by Plastic Explosives
Popis výsledku v původním jazyce
The chapter presents the results of experimental tests carried out on steel fiber reinforced concrete slabs and on unreinforced concrete slabs. The aim of the experimental tests was to determine its suitability for anti-spalling layer by using effects of plastic explosive PlHx 30 explosion. Slabs of steel fiber reinforced concrete and of plain concrete were made according to the same recipe. For this experiment, high-strength concrete with strength class C70/85 was used. In the mixture of steel fiber reinforced concrete, it was added 30 kg of fibers per 1 m3, type Dramix RC-65/50-BN. The interior surface of shelters walls must be protected against the concrete spalling, which are caused by detonations on the outside surface. The results of the tests proved that steel fiber reinforced concrete is not a suitable material for the anti-spalling layer.
Název v anglickém jazyce
Experimental Ballistic Loading of Steel Fiber Reinforced Concrete Slabs and Unreinforced Concrete Slabs by Plastic Explosives
Popis výsledku anglicky
The chapter presents the results of experimental tests carried out on steel fiber reinforced concrete slabs and on unreinforced concrete slabs. The aim of the experimental tests was to determine its suitability for anti-spalling layer by using effects of plastic explosive PlHx 30 explosion. Slabs of steel fiber reinforced concrete and of plain concrete were made according to the same recipe. For this experiment, high-strength concrete with strength class C70/85 was used. In the mixture of steel fiber reinforced concrete, it was added 30 kg of fibers per 1 m3, type Dramix RC-65/50-BN. The interior surface of shelters walls must be protected against the concrete spalling, which are caused by detonations on the outside surface. The results of the tests proved that steel fiber reinforced concrete is not a suitable material for the anti-spalling layer.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
50901 - Other social sciences
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Durability of Critical Infrastructure, Monitoring and Testing - Lecture Notes in Mechanical Engineering
ISBN
978-981-10-3246-2
ISSN
2195-4356
e-ISSN
—
Počet stran výsledku
10
Strana od-do
110-119
Název nakladatele
SPRINGER-VERLAG SINGAPORE PTE LTD, SINGAPORE
Místo vydání
SINGAPORE
Místo konání akce
Satov, CZECH REPUBLIC
Datum konání akce
6. 12. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000419058500013