Evaluation Methodology and Measurement of Physiological Data to Determine Operational Preparedness of Air Defense Staff: Preliminary Results
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG43__%2F19%3A00535192" target="_blank" >RIV/60162694:G43__/19:00535192 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21460/19:00321942
Výsledek na webu
<a href="http://dx.doi.org/10.1007/978-981-10-9035-6_64" target="_blank" >http://dx.doi.org/10.1007/978-981-10-9035-6_64</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-981-10-9035-6_64" target="_blank" >10.1007/978-981-10-9035-6_64</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation Methodology and Measurement of Physiological Data to Determine Operational Preparedness of Air Defense Staff: Preliminary Results
Popis výsledku v původním jazyce
The aim of the article is to introduce new evaluation methodology to determine operational preparedness of air defense staff based on measurement of physiological data. The individuals working with air defense systems are under very high level of stress and long-term monotone air picture observation workload during the mission. We designed an experiment and a method of measuring the biomedical signals for monitoring the actual operator condition during long-term work on air picture simulator that shows real-time aircraft flight information. Long-term monitoring and recording of potential airborne targets in the area of interest to which operators are subjected is accompanied by monitoring the physiological data such as heart rate, body temperature, movement activity and perspiration intensity of operators. The proposed methodology and measurements were tested on four air defense system operators of the Army of the Czech Republic. Operators took part in a four-hour intensive measurement without any break and their training was evaluated. Designed methods could help to monitor, on the base of physiological data and data from simulators, the stress load level and operational preparedness.
Název v anglickém jazyce
Evaluation Methodology and Measurement of Physiological Data to Determine Operational Preparedness of Air Defense Staff: Preliminary Results
Popis výsledku anglicky
The aim of the article is to introduce new evaluation methodology to determine operational preparedness of air defense staff based on measurement of physiological data. The individuals working with air defense systems are under very high level of stress and long-term monotone air picture observation workload during the mission. We designed an experiment and a method of measuring the biomedical signals for monitoring the actual operator condition during long-term work on air picture simulator that shows real-time aircraft flight information. Long-term monitoring and recording of potential airborne targets in the area of interest to which operators are subjected is accompanied by monitoring the physiological data such as heart rate, body temperature, movement activity and perspiration intensity of operators. The proposed methodology and measurements were tested on four air defense system operators of the Army of the Czech Republic. Operators took part in a four-hour intensive measurement without any break and their training was evaluated. Designed methods could help to monitor, on the base of physiological data and data from simulators, the stress load level and operational preparedness.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20204 - Robotics and automatic control
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
The World Congress on Medical Physics and Biomedical Engineering 2018 (WC2018)
ISBN
978-981-10-9034-9
ISSN
1680-0737
e-ISSN
—
Počet stran výsledku
5
Strana od-do
351-355
Název nakladatele
Springer Verlag
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
3. 6. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000450908300064