Using wavelength multiplex and optical circulators for power-supply temperature fiber-optic polarization sensor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG43__%2F23%3A00558828" target="_blank" >RIV/60162694:G43__/23:00558828 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.eeict.cz/eeict_download/archiv/sborniky/EEICT_2022_sbornik_1_v2.pdf" target="_blank" >https://www.eeict.cz/eeict_download/archiv/sborniky/EEICT_2022_sbornik_1_v2.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Using wavelength multiplex and optical circulators for power-supply temperature fiber-optic polarization sensor
Popis výsledku v původním jazyce
A temperature fiber-optic polarization sensor, which thanks to its non-electricity, inertness to its surroundings, and high sensitivity is suitable for remote sensing in dangerous environments with a high risk of explosion, can be power-supplied via classical single mode fiber. The research investigates the use of a wavelength multiplex of 1550 and 1557,36 nm, and connections of polarization maintaining circulators, optical routes, and couplers to ensure quality power-supply to the sensor and parallel data transmitting. Separately, without the connected sensor, data transmission was successful without problems. With a connected sensor, due to the whole concept of a circuit caused problems, and data transmission was not working. Sensor sensitivity was tested by the application of a container with water at different temperatures. Experiments show that sensor sensitivity is not negatively affected by data transmission, it only affects outgoing level of power.
Název v anglickém jazyce
Using wavelength multiplex and optical circulators for power-supply temperature fiber-optic polarization sensor
Popis výsledku anglicky
A temperature fiber-optic polarization sensor, which thanks to its non-electricity, inertness to its surroundings, and high sensitivity is suitable for remote sensing in dangerous environments with a high risk of explosion, can be power-supplied via classical single mode fiber. The research investigates the use of a wavelength multiplex of 1550 and 1557,36 nm, and connections of polarization maintaining circulators, optical routes, and couplers to ensure quality power-supply to the sensor and parallel data transmitting. Separately, without the connected sensor, data transmission was successful without problems. With a connected sensor, due to the whole concept of a circuit caused problems, and data transmission was not working. Sensor sensitivity was tested by the application of a container with water at different temperatures. Experiments show that sensor sensitivity is not negatively affected by data transmission, it only affects outgoing level of power.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings I of the 28th Conference STUDENT EEICT 2022
ISBN
978-80-214-6029-4
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
216-219
Název nakladatele
Brno University of Technology, Faculty of Electrical Engineering and Communication
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
26. 4. 2022
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—