0.5-V 16 nW Low-Pass Filter for Bio-Signal Applications
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG43__%2F25%3A00563589" target="_blank" >RIV/60162694:G43__/25:00563589 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26220/24:PU152704
Výsledek na webu
<a href="http://ieeexplore.ieee.org/xpl/mostRecentIssue.jsp?punumber=10594802" target="_blank" >http://ieeexplore.ieee.org/xpl/mostRecentIssue.jsp?punumber=10594802</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ECTI-CON60892.2024.10594879" target="_blank" >10.1109/ECTI-CON60892.2024.10594879</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
0.5-V 16 nW Low-Pass Filter for Bio-Signal Applications
Popis výsledku v původním jazyce
This study presents a low-voltage, ultra-low power fully-differential low-pass filter for bio-signal applications using multiple-input fully differential operational transconductance amplifiers (MIFD OTA). This work shows that a low-pass filter using multiple-input OTA can reduce the number of OTAs and power consumption. The low-pass filter can be applied to biomedical signal processing applications. The low-pass filter was simulated using the 0.18 μm (CMOS) technology from TSMC with a supply voltage of 0.5 V. The simulation result shows that the filter has a static power consumption of 16 nW and a 140-Hz bandwidth when operating from a supply voltage of 0.5 V. Input frequency of 10 Hz with an amplitude of 220 mV, the new proposed filter provides a dynamic range of 72.2 dB, total harmonic distortion of 1 %.
Název v anglickém jazyce
0.5-V 16 nW Low-Pass Filter for Bio-Signal Applications
Popis výsledku anglicky
This study presents a low-voltage, ultra-low power fully-differential low-pass filter for bio-signal applications using multiple-input fully differential operational transconductance amplifiers (MIFD OTA). This work shows that a low-pass filter using multiple-input OTA can reduce the number of OTAs and power consumption. The low-pass filter can be applied to biomedical signal processing applications. The low-pass filter was simulated using the 0.18 μm (CMOS) technology from TSMC with a supply voltage of 0.5 V. The simulation result shows that the filter has a static power consumption of 16 nW and a 140-Hz bandwidth when operating from a supply voltage of 0.5 V. Input frequency of 10 Hz with an amplitude of 220 mV, the new proposed filter provides a dynamic range of 72.2 dB, total harmonic distortion of 1 %.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2024 21st International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology, ECTI-CON 2024
ISBN
979-8-3503-8155-9
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
Institute of Electrical and Electronics Engineers Inc.
Místo vydání
Thailand
Místo konání akce
Khon Kaen, Kingdom of Thailand
Datum konání akce
27. 5. 2024
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—