Diagnoses Based on C-Reactive Protein Point-of-Care Tests
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG44__%2F23%3A00558101" target="_blank" >RIV/60162694:G44__/23:00558101 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.mdpi.com/2079-6374/12/5/344" target="_blank" >https://www.mdpi.com/2079-6374/12/5/344</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/bios12050344" target="_blank" >10.3390/bios12050344</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Diagnoses Based on C-Reactive Protein Point-of-Care Tests
Popis výsledku v původním jazyce
C-reactive protein (CRP) is an important part of the immune system's reaction to various pathological impulses such as bacterial infections, systemic inflammation, and internal organ failures. An increased CRP level serves to diagnose the mentioned pathological states. Both standard laboratory methods and simple point-of-care devices such as lateral flow tests and immunoturbidimetric assays serve for the instrumental diagnoses based on CRP. The current method for CRP has many flaws and limitations in its use. Biosensor and bioassay analytical devices are presently researched by many teams to provide more sensitive and better-suited tools for point-of-care tests of CRP in biological samples when compared to the standard methods. This review article is focused on mapping the diagnostical relevance of CRP, the applicability of the current analytical methods, and the recent innovations in the measurement of CRP level.
Název v anglickém jazyce
Diagnoses Based on C-Reactive Protein Point-of-Care Tests
Popis výsledku anglicky
C-reactive protein (CRP) is an important part of the immune system's reaction to various pathological impulses such as bacterial infections, systemic inflammation, and internal organ failures. An increased CRP level serves to diagnose the mentioned pathological states. Both standard laboratory methods and simple point-of-care devices such as lateral flow tests and immunoturbidimetric assays serve for the instrumental diagnoses based on CRP. The current method for CRP has many flaws and limitations in its use. Biosensor and bioassay analytical devices are presently researched by many teams to provide more sensitive and better-suited tools for point-of-care tests of CRP in biological samples when compared to the standard methods. This review article is focused on mapping the diagnostical relevance of CRP, the applicability of the current analytical methods, and the recent innovations in the measurement of CRP level.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biosensors
ISSN
2079-6374
e-ISSN
2079-6374
Svazek periodika
12
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
17
Strana od-do
344
Kód UT WoS článku
000801285000001
EID výsledku v databázi Scopus
2-s2.0-85130857029