A system for wireless measurement of human biomechanics
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG44__%2F25%3A00564183" target="_blank" >RIV/60162694:G44__/25:00564183 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.mmsl.cz/pdfs/mms/2024/04/02.pdf" target="_blank" >https://www.mmsl.cz/pdfs/mms/2024/04/02.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.31482/mmsl.2023.038" target="_blank" >10.31482/mmsl.2023.038</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A system for wireless measurement of human biomechanics
Popis výsledku v původním jazyce
Background Femoroacetabular impingement syndrome (FAI) is a complex, often post-traumatically developing impairment of the hip joint. It is characterized by ambiguous symptomatology, which makes early diagnosis difficult. Aim The study was conducted to evaluate the applicability of a triaxial gyroscopic sensor in routine practice as an additional indication criterion for operative versus conservative treatment procedures. Methods Ninety-two patients were included in the experimental retrospective study and 62 completed the examination. All patients signed informed consent. A gyroscopic sensor was placed on the right side of the pelvis above the hip joint and patients walked approximately 15 steps. Data were also evaluated while the patients climbed stairs. A complete clinical examination of the dynamics and physiological movements in the joint was performed. The data measured by the gyroscopic sensor were processed using differential geometry methods and subsequently evaluated using spectral analysis and neural networks. Results FAI diagnosis using gyroscopic measurement is fast and easy to implement. Our approach to processing the gyroscopic signals used to detect the stage of osteoarthritis and post-traumatic FAI could lead to more accurate detection and capture early in FAI development. Conclusions The obtained data are easily evaluated, interpretable, and beneficial in the diagnosis of the early stages of FAI. The results of the study show that this approach can lead to more accurate and early detection of osteoarthritis and post-traumatic FAI.
Název v anglickém jazyce
A system for wireless measurement of human biomechanics
Popis výsledku anglicky
Background Femoroacetabular impingement syndrome (FAI) is a complex, often post-traumatically developing impairment of the hip joint. It is characterized by ambiguous symptomatology, which makes early diagnosis difficult. Aim The study was conducted to evaluate the applicability of a triaxial gyroscopic sensor in routine practice as an additional indication criterion for operative versus conservative treatment procedures. Methods Ninety-two patients were included in the experimental retrospective study and 62 completed the examination. All patients signed informed consent. A gyroscopic sensor was placed on the right side of the pelvis above the hip joint and patients walked approximately 15 steps. Data were also evaluated while the patients climbed stairs. A complete clinical examination of the dynamics and physiological movements in the joint was performed. The data measured by the gyroscopic sensor were processed using differential geometry methods and subsequently evaluated using spectral analysis and neural networks. Results FAI diagnosis using gyroscopic measurement is fast and easy to implement. Our approach to processing the gyroscopic signals used to detect the stage of osteoarthritis and post-traumatic FAI could lead to more accurate detection and capture early in FAI development. Conclusions The obtained data are easily evaluated, interpretable, and beneficial in the diagnosis of the early stages of FAI. The results of the study show that this approach can lead to more accurate and early detection of osteoarthritis and post-traumatic FAI.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
30212 - Surgery
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Military Medical Science Letetrs
ISSN
0372-7025
e-ISSN
2571-113X
Svazek periodika
93
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
12
Strana od-do
323-334
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—