Popis výsledku v původním jazyce
Measurement of constructive materials resistance against under interest toxic compounds has a huge importance not only from the point of user´s view but also commercial one. Within both accesses it is necessary to differ an amount of permeated under interest permeated toxic compound through protective material. If it is demanded penetration of exactly determinated amount of toxic compound through material for protective materials´ quality assessment for purposes of their mutual comparison so from the point of user´s point of view should have been reckoned with either toxicological characteristic of toxic compound permeated through barrier material or to determine a maximum amount of toxic compound which is still allow to penetrate. The PIEZOTEST deviceis designed for measurement of square constructive materials used in body surface protection´s resistance. Commercially delivered device cannot be able to perform calibration. The aim of this information is to present calibration solutio
Název v anglickém jazyce
Calibration Extension for Permeation Cell of PIEZOTEST Device
Popis výsledku anglicky
Measurement of constructive materials resistance against under interest toxic compounds has a huge importance not only from the point of user´s view but also commercial one. Within both accesses it is necessary to differ an amount of permeated under interest permeated toxic compound through protective material. If it is demanded penetration of exactly determinated amount of toxic compound through material for protective materials´ quality assessment for purposes of their mutual comparison so from the point of user´s point of view should have been reckoned with either toxicological characteristic of toxic compound permeated through barrier material or to determine a maximum amount of toxic compound which is still allow to penetrate. The PIEZOTEST deviceis designed for measurement of square constructive materials used in body surface protection´s resistance. Commercially delivered device cannot be able to perform calibration. The aim of this information is to present calibration solutio
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
KA - Vojenství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Advances in Military Technology
ISSN
1802-2308
e-ISSN
—
Svazek periodika
7
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
8
Strana od-do
33-40