Resistance of the Isolative Protective Garment designated for Specialists´ Protection against Selected Chlorinated Hydrocarbons
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG45__%2F14%3A00519536" target="_blank" >RIV/60162694:G45__/14:00519536 - isvavai.cz</a>
Výsledek na webu
<a href="http://vavtest.unob.cz/registr" target="_blank" >http://vavtest.unob.cz/registr</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Resistance of the Isolative Protective Garment designated for Specialists´ Protection against Selected Chlorinated Hydrocarbons
Popis výsledku v původním jazyce
Chlorinated hydrocarbons are very often used and are relatively dangerous substances from healthy risk point of view. While manipulating with them, mainly in large volumes, individual protective equipment (IPE) must be used in a protection position. Users are supposed to know the construction material breakthrough time especially in case of long-term usage of personal IPE and in the situation when contamination of them is real. Studying connections between a chemical compound structure and the structureof IPE characterised by barrier materials enables us to understand present body protective devices protection quality and gives us an optionto choose barrier materials with targeted properties. In this article there are results of breakthrough time of isolating protection folio with a butyl rubber barrier layer in relation to chlorinated ethanes. This material is used for protection of specialists of both Fire Rescue Brigades and the Czech Armed Forces Chemical Corps. The PIEZOTEST devi
Název v anglickém jazyce
Resistance of the Isolative Protective Garment designated for Specialists´ Protection against Selected Chlorinated Hydrocarbons
Popis výsledku anglicky
Chlorinated hydrocarbons are very often used and are relatively dangerous substances from healthy risk point of view. While manipulating with them, mainly in large volumes, individual protective equipment (IPE) must be used in a protection position. Users are supposed to know the construction material breakthrough time especially in case of long-term usage of personal IPE and in the situation when contamination of them is real. Studying connections between a chemical compound structure and the structureof IPE characterised by barrier materials enables us to understand present body protective devices protection quality and gives us an optionto choose barrier materials with targeted properties. In this article there are results of breakthrough time of isolating protection folio with a butyl rubber barrier layer in relation to chlorinated ethanes. This material is used for protection of specialists of both Fire Rescue Brigades and the Czech Armed Forces Chemical Corps. The PIEZOTEST devi
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
KA - Vojenství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Vojenské zdravotnické listy
ISSN
0372-7025
e-ISSN
—
Svazek periodika
83
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
11-17
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—