Contaminated disposable rubber gloves as evidence samples after a chemical attack with nerve agents
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG45__%2F24%3A00558974" target="_blank" >RIV/60162694:G45__/24:00558974 - isvavai.cz</a>
Výsledek na webu
<a href="http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1942-7611" target="_blank" >http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1942-7611</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/dta.3468" target="_blank" >10.1002/dta.3468</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Contaminated disposable rubber gloves as evidence samples after a chemical attack with nerve agents
Popis výsledku v původním jazyce
Nerve agents have been used recently in the Syrian civil war. Collecting relevant samples for retrospective identification of an attack is often problematic. The article deals with the possibility of using contaminated gloves as an analytical sample for evidence of the chemical weapons use. There have not yet been published studies dealing with the identification of chemical warfare agents in this type of matrix, where the diversity of chemical properties of gloves and the lifetime of the contaminated sample would be considered. Sarin, soman, and cyclosarin were used as contaminants in the study. Nitrile, latex, and vinyl disposable gloves were chosen as matrices. The identification method was gas chromatography. Six solvents commonly used in military laboratories were tested as extractants. The extraction procedure was optimized in terms of the appropriate method (vortex) and the required extraction time (1 min) and resulted in significant reduction in sample preparation time. The chromatographic background of the extracts was also monitored in order to find a method with the least number of peaks interfering in the identification. Suitable solvents were hexane and acetonitrile. The lifetime of the sample was also investigated. The worst result was recorded for latex. For individual contaminants, the time varied depending on the volatility. The developed procedures were successfully validated within a sample handling effects scenario. The results demonstrate that in the event of an ongoing military risk at the site of an attack, even discarded disposable rubber glove type samples can be used as evidence.
Název v anglickém jazyce
Contaminated disposable rubber gloves as evidence samples after a chemical attack with nerve agents
Popis výsledku anglicky
Nerve agents have been used recently in the Syrian civil war. Collecting relevant samples for retrospective identification of an attack is often problematic. The article deals with the possibility of using contaminated gloves as an analytical sample for evidence of the chemical weapons use. There have not yet been published studies dealing with the identification of chemical warfare agents in this type of matrix, where the diversity of chemical properties of gloves and the lifetime of the contaminated sample would be considered. Sarin, soman, and cyclosarin were used as contaminants in the study. Nitrile, latex, and vinyl disposable gloves were chosen as matrices. The identification method was gas chromatography. Six solvents commonly used in military laboratories were tested as extractants. The extraction procedure was optimized in terms of the appropriate method (vortex) and the required extraction time (1 min) and resulted in significant reduction in sample preparation time. The chromatographic background of the extracts was also monitored in order to find a method with the least number of peaks interfering in the identification. Suitable solvents were hexane and acetonitrile. The lifetime of the sample was also investigated. The worst result was recorded for latex. For individual contaminants, the time varied depending on the volatility. The developed procedures were successfully validated within a sample handling effects scenario. The results demonstrate that in the event of an ongoing military risk at the site of an attack, even discarded disposable rubber glove type samples can be used as evidence.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Drug Testing and Analysis
ISSN
1942-7603
e-ISSN
1942-7611
Svazek periodika
15
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
12
Strana od-do
745-756
Kód UT WoS článku
000972622400001
EID výsledku v databázi Scopus
2-s2.0-85150814992