Mobilita významných toxických analytů v městském prachu a simulovaných prachových filtrech stanovená metodou postupné extrakce a metodami GFAAS a ICP-OES
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41210%2F06%3A15854" target="_blank" >RIV/60460709:41210/06:15854 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Mobility of Important Toxic Analytes in Urban Dust and Simulated Air Filters Determined by Sequential Extraction and GFAAS/ICP-AES Methods
Popis výsledku v původním jazyce
The modified BCR three step sequential extraction procedure has been applied to homogenized urban dust samples (APM) and to simulated air filters (acetyl cellulose, diameter of 47 mm and pore size 0.45 μm) loaded with APM by the wet deposition process. Differences between extracted portions of analytes in APM and in simulated air filters were found, the mobility of some analytes in case of simulated air filters was higher. Namely, in exchangeable fraction F1 Cd, Mn and Pb showed an increase in therange 25-40%, in fraction F2 concentrations of As, Cr, Mn and Ni increased in the range of 11-20% and in fraction F3 the significant increase for As (43%), Cr (25%) and Ni (32%) was observed. The APM extraction procedure in presence of surfactant TritonX-100 (0.05 % v/v) was also investigated and the concentration enhancement in mobile and possible mobile fractions of most analytes was observed as well.
Název v anglickém jazyce
Mobility of Important Toxic Analytes in Urban Dust and Simulated Air Filters Determined by Sequential Extraction and GFAAS/ICP-AES Methods
Popis výsledku anglicky
The modified BCR three step sequential extraction procedure has been applied to homogenized urban dust samples (APM) and to simulated air filters (acetyl cellulose, diameter of 47 mm and pore size 0.45 μm) loaded with APM by the wet deposition process. Differences between extracted portions of analytes in APM and in simulated air filters were found, the mobility of some analytes in case of simulated air filters was higher. Namely, in exchangeable fraction F1 Cd, Mn and Pb showed an increase in therange 25-40%, in fraction F2 concentrations of As, Cr, Mn and Ni increased in the range of 11-20% and in fraction F3 the significant increase for As (43%), Cr (25%) and Ni (32%) was observed. The APM extraction procedure in presence of surfactant TritonX-100 (0.05 % v/v) was also investigated and the concentration enhancement in mobile and possible mobile fractions of most analytes was observed as well.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
18. Slovenská spektroskopická konference
ISBN
80-223-2244-X
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
121-121
Název nakladatele
Univerzita Bratislava
Místo vydání
Bratislava
Místo konání akce
Spišská Nová Ves
Datum konání akce
15. 10. 2006
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—