Vše

Co hledáte?

Vše
Projekty
Výsledky výzkumu
Subjekty

Rychlé hledání

  • Projekty podpořené TA ČR
  • Významné projekty
  • Projekty s nejvyšší státní podporou
  • Aktuálně běžící projekty

Chytré vyhledávání

  • Takto najdu konkrétní +slovo
  • Takto z výsledků -slovo zcela vynechám
  • “Takto můžu najít celou frázi”

Development of an Automated Tension Infi ltrometer for Field Use

Identifikátory výsledku

  • Kód výsledku v IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41210%2F09%3A30823" target="_blank" >RIV/60460709:41210/09:30823 - isvavai.cz</a>

  • Výsledek na webu

  • DOI - Digital Object Identifier

Alternativní jazyky

  • Jazyk výsledku

    angličtina

  • Název v původním jazyce

    Development of an Automated Tension Infi ltrometer for Field Use

  • Popis výsledku v původním jazyce

    Tension infiltrometry is a useful in situ technique that is commonly used to determine hydraulic conductivity of the soil near saturation; however, the measurements are time consuming and costly. The aim of this study was to develop a fully automated tension infiltrometer for field use based on already existing designs. Differential pressure transducers were used to automate water level measurements, and the tension settings were automated by a set of solenoid valves. The effects of different design parameters on water level measurement fluctuations created by bubble disturbances (noise) were studied in the laboratory. The differential transducer provided less noisy measurements than the single transducer. The measurement noise was significantly smaller when a large-diameter reservoir was used. The measurement noise was further reduced by using a reservoir system made of two tubes of different diameters slotted into each other. The effect of an increasing flow rate on the water level f

  • Název v anglickém jazyce

    Development of an Automated Tension Infi ltrometer for Field Use

  • Popis výsledku anglicky

    Tension infiltrometry is a useful in situ technique that is commonly used to determine hydraulic conductivity of the soil near saturation; however, the measurements are time consuming and costly. The aim of this study was to develop a fully automated tension infiltrometer for field use based on already existing designs. Differential pressure transducers were used to automate water level measurements, and the tension settings were automated by a set of solenoid valves. The effects of different design parameters on water level measurement fluctuations created by bubble disturbances (noise) were studied in the laboratory. The differential transducer provided less noisy measurements than the single transducer. The measurement noise was significantly smaller when a large-diameter reservoir was used. The measurement noise was further reduced by using a reservoir system made of two tubes of different diameters slotted into each other. The effect of an increasing flow rate on the water level f

Klasifikace

  • Druh

    J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)

  • CEP obor

    DF - Pedologie

  • OECD FORD obor

Návaznosti výsledku

  • Projekt

    <a href="/cs/project/1G58095" target="_blank" >1G58095: Předpovědní půdně-agrohydrologické modely retence vody v půdě v ČR a jejich integrace do databází zemí EU</a><br>

  • Návaznosti

    Z - Vyzkumny zamer (s odkazem do CEZ)

Ostatní

  • Rok uplatnění

    2009

  • Kód důvěrnosti údajů

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Údaje specifické pro druh výsledku

  • Název periodika

    Vadose Zone Journal

  • ISSN

    1539-1663

  • e-ISSN

  • Svazek periodika

    8

  • Číslo periodika v rámci svazku

    3

  • Stát vydavatele periodika

    US - Spojené státy americké

  • Počet stran výsledku

    8

  • Strana od-do

  • Kód UT WoS článku

  • EID výsledku v databázi Scopus