Development of an Automated Tension Infi ltrometer for Field Use
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41210%2F09%3A30823" target="_blank" >RIV/60460709:41210/09:30823 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development of an Automated Tension Infi ltrometer for Field Use
Popis výsledku v původním jazyce
Tension infiltrometry is a useful in situ technique that is commonly used to determine hydraulic conductivity of the soil near saturation; however, the measurements are time consuming and costly. The aim of this study was to develop a fully automated tension infiltrometer for field use based on already existing designs. Differential pressure transducers were used to automate water level measurements, and the tension settings were automated by a set of solenoid valves. The effects of different design parameters on water level measurement fluctuations created by bubble disturbances (noise) were studied in the laboratory. The differential transducer provided less noisy measurements than the single transducer. The measurement noise was significantly smaller when a large-diameter reservoir was used. The measurement noise was further reduced by using a reservoir system made of two tubes of different diameters slotted into each other. The effect of an increasing flow rate on the water level f
Název v anglickém jazyce
Development of an Automated Tension Infi ltrometer for Field Use
Popis výsledku anglicky
Tension infiltrometry is a useful in situ technique that is commonly used to determine hydraulic conductivity of the soil near saturation; however, the measurements are time consuming and costly. The aim of this study was to develop a fully automated tension infiltrometer for field use based on already existing designs. Differential pressure transducers were used to automate water level measurements, and the tension settings were automated by a set of solenoid valves. The effects of different design parameters on water level measurement fluctuations created by bubble disturbances (noise) were studied in the laboratory. The differential transducer provided less noisy measurements than the single transducer. The measurement noise was significantly smaller when a large-diameter reservoir was used. The measurement noise was further reduced by using a reservoir system made of two tubes of different diameters slotted into each other. The effect of an increasing flow rate on the water level f
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DF - Pedologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1G58095" target="_blank" >1G58095: Předpovědní půdně-agrohydrologické modely retence vody v půdě v ČR a jejich integrace do databází zemí EU</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Vadose Zone Journal
ISSN
1539-1663
e-ISSN
—
Svazek periodika
8
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—