Air-conditioning and microbiological environment in the lecture room
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41210%2F14%3A63979" target="_blank" >RIV/60460709:41210/14:63979 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60460709:41310/14:63979
Výsledek na webu
<a href="http://dx.doi.org/10.7160/sab.2014.450205" target="_blank" >http://dx.doi.org/10.7160/sab.2014.450205</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.7160/sab.2014.450205" target="_blank" >10.7160/sab.2014.450205</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Air-conditioning and microbiological environment in the lecture room
Popis výsledku v původním jazyce
The influence of air-conditioning system and equipment on the indoor environmental conditions inside the lecture room of the Czech University of Life Sciences Prague is described. The microbial contamination (filamentous fungi and bacteria) and also themain microclimatic parameters of the air, temperature and relative humidity of air, were measured and evaluated in relation to different performance conditions of the lecture room. Predominant bacteria detected were Gram-positive cocci, Micrococcus spp.,Staphylococcus spp., and endospore-forming bacilli (Bacillus spp., Bacillus mycoides). The intensity of air-conditioning influenced the quality of indoor environment in the room. 15 min after starting the air-conditioning the number of airborne bacteriain the lecture room decreased to 35-40 and later on to 20. Conidia of microscopic filamentous fungi were passing through the filters for outdoor air filtering (non-woven polyester fabrics Firon Special G 460 for coarse dust, class filtra
Název v anglickém jazyce
Air-conditioning and microbiological environment in the lecture room
Popis výsledku anglicky
The influence of air-conditioning system and equipment on the indoor environmental conditions inside the lecture room of the Czech University of Life Sciences Prague is described. The microbial contamination (filamentous fungi and bacteria) and also themain microclimatic parameters of the air, temperature and relative humidity of air, were measured and evaluated in relation to different performance conditions of the lecture room. Predominant bacteria detected were Gram-positive cocci, Micrococcus spp.,Staphylococcus spp., and endospore-forming bacilli (Bacillus spp., Bacillus mycoides). The intensity of air-conditioning influenced the quality of indoor environment in the room. 15 min after starting the air-conditioning the number of airborne bacteriain the lecture room decreased to 35-40 and later on to 20. Conidia of microscopic filamentous fungi were passing through the filters for outdoor air filtering (non-woven polyester fabrics Firon Special G 460 for coarse dust, class filtra
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EE - Mikrobiologie, virologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Scientia Agriculturae Bohemica
ISSN
1211-3174
e-ISSN
—
Svazek periodika
45
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
104-109
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—