Concentration of air-borne microorganisms in sport facilities
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41210%2F18%3A78001" target="_blank" >RIV/60460709:41210/18:78001 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60460709:41310/18:78001
Výsledek na webu
<a href="http://dx.doi.org/10.15159/AR.18.149" target="_blank" >http://dx.doi.org/10.15159/AR.18.149</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.15159/AR.18.149" target="_blank" >10.15159/AR.18.149</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Concentration of air-borne microorganisms in sport facilities
Popis výsledku v původním jazyce
This paper is focused on the microclimatic research in several buildings and rooms used for sport at the University. The attention is paid mainly to the problems of dimensions of space, capacity and activity of sportsmen, and influence of space ventilation. The air samples for microbiological analyses were taken by the microbial air sampler Merck Mas-100 Eco and cultivated by potato-dextrose agar and nutrient agar. Captured microorganisms, are expressed as colony forming units per m3 (CFU m-3). Measurement results showed that bacteria average quantity was statistically significantly less without students (562 CFU m-3) than with students (1,024 CFU m-3). The students inside the rooms increased the bacteria concentration. From this point of view the ventilation is not adequate for the removal of bacteria from ventilated spaces. From the results we can conclude that the great importance on the air quality in terms of a specific bacteria concentration has the specific volume of the room per o
Název v anglickém jazyce
Concentration of air-borne microorganisms in sport facilities
Popis výsledku anglicky
This paper is focused on the microclimatic research in several buildings and rooms used for sport at the University. The attention is paid mainly to the problems of dimensions of space, capacity and activity of sportsmen, and influence of space ventilation. The air samples for microbiological analyses were taken by the microbial air sampler Merck Mas-100 Eco and cultivated by potato-dextrose agar and nutrient agar. Captured microorganisms, are expressed as colony forming units per m3 (CFU m-3). Measurement results showed that bacteria average quantity was statistically significantly less without students (562 CFU m-3) than with students (1,024 CFU m-3). The students inside the rooms increased the bacteria concentration. From this point of view the ventilation is not adequate for the removal of bacteria from ventilated spaces. From the results we can conclude that the great importance on the air quality in terms of a specific bacteria concentration has the specific volume of the room per o
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
10606 - Microbiology
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Agronomy Research
ISSN
1406-894X
e-ISSN
—
Svazek periodika
16
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
8
Strana od-do
1720-1727
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85059701320