Quality of the lyzimetric water under grass and legumes stands on arable land
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41210%2F99%3A00000386" target="_blank" >RIV/60460709:41210/99:00000386 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Quality of the lyzimetric water under grass and legumes stands on arable land
Popis výsledku v původním jazyce
A field plot trial (1 plot 3x10m) was established in 1996 on the experimental field of the Czech University of Agriculture in Prague. The stans were harvested four ways: cut 3 times with crop removed; cut once at the end of the growth period with the crop removed; mulched two times; mulched once.To measure the quality of ground water static field lysimeters were built at a depth 0.5m under undamaged soil profiles of each of the variants. Lysimeter water samples were taken at 2 times-the beginning (March-April) and at the end (October-November) of the growth period. Between the mulched variants, when the growth the twice mulched growth shows about 25,83% higher leaching of NO3-N then the growth of the once mulched. There were no changes between the oneand three times cutting systems.
Název v anglickém jazyce
Quality of the lyzimetric water under grass and legumes stands on arable land
Popis výsledku anglicky
A field plot trial (1 plot 3x10m) was established in 1996 on the experimental field of the Czech University of Agriculture in Prague. The stans were harvested four ways: cut 3 times with crop removed; cut once at the end of the growth period with the crop removed; mulched two times; mulched once.To measure the quality of ground water static field lysimeters were built at a depth 0.5m under undamaged soil profiles of each of the variants. Lysimeter water samples were taken at 2 times-the beginning (March-April) and at the end (October-November) of the growth period. Between the mulched variants, when the growth the twice mulched growth shows about 25,83% higher leaching of NO3-N then the growth of the once mulched. There were no changes between the oneand three times cutting systems.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
DJ - Znečištění a kontrola vody
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
1999
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Mezinárodní konference
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
—
Název nakladatele
Slovenská spoločnost pre polnohospodárske,lesnícke,potravinárske a veterinárne vedy pri Slovenskej akadémii vied
Místo vydání
Banská Bystrica
Místo konání akce
—
Datum konání akce
—
Typ akce podle státní příslušnosti
—
Kód UT WoS článku
—