Towards 50 years lifetime of PV panels laminated with silicone gel technology
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41310%2F12%3A55101" target="_blank" >RIV/60460709:41310/12:55101 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Towards 50 years lifetime of PV panels laminated with silicone gel technology
Popis výsledku v původním jazyce
A silicone gel lamination technology of PV panels has been developed and gel lamination apparatus with an annual production capacity of 1 MWp has been designed and manufactured. Silicone gel laminated c-Si PV panels were prepared and tested at 3.5 timesconcentrated solar radiation in the UV chamber. Negligible corrosion of silicone gel laminated PV panels was observed in comparison with EVA laminated panels. In contrast to EVA-laminated panels the transparency reduction induced by UV radiation in silicone gel lamination is very small. Production of silicone gel laminated PV panels with 50 years lifetime could be achievable because of the strongly reduced corrosiveness which is main source of failures in commercial PV panels.
Název v anglickém jazyce
Towards 50 years lifetime of PV panels laminated with silicone gel technology
Popis výsledku anglicky
A silicone gel lamination technology of PV panels has been developed and gel lamination apparatus with an annual production capacity of 1 MWp has been designed and manufactured. Silicone gel laminated c-Si PV panels were prepared and tested at 3.5 timesconcentrated solar radiation in the UV chamber. Negligible corrosion of silicone gel laminated PV panels was observed in comparison with EVA laminated panels. In contrast to EVA-laminated panels the transparency reduction induced by UV radiation in silicone gel lamination is very small. Production of silicone gel laminated PV panels with 50 years lifetime could be achievable because of the strongly reduced corrosiveness which is main source of failures in commercial PV panels.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
SOLAR ENERGY
ISSN
0038-092X
e-ISSN
—
Svazek periodika
86
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
3103-3108
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—