Influence of biofuel moisture content on combustion and emission characteristics of stove
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41310%2F16%3A70457" target="_blank" >RIV/60460709:41310/16:70457 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of biofuel moisture content on combustion and emission characteristics of stove
Popis výsledku v původním jazyce
The research aim was to study the effect of moisture in solid fuel on combustion in a stove and its emissions. Analysed samples were from spruce woodchips. Four samples were prepared with different moisture contents and furthermore spruce wood was used as a reference sample. Combustion device used was a stove with a fixed fire grate. Studied parameters were ambient temperature, temperature of flue gases, coefficient of excess air, and contents of oxygen and carbon monoxide in flue gases. Laboratory measurement was performed on an analyser of flue gases whose function is based on electro-chemical converters. Measured values were first converted to a referential oxygen content in flue gases. Evaluation of these values was then made by regression analyses. The course of combustion process and its quality can be seen well in functional dependence of carbon monoxide on excess air coefficient. The area of combustion was the smallest with the least moist sample (3.2%) and increases with increasing moisture.
Název v anglickém jazyce
Influence of biofuel moisture content on combustion and emission characteristics of stove
Popis výsledku anglicky
The research aim was to study the effect of moisture in solid fuel on combustion in a stove and its emissions. Analysed samples were from spruce woodchips. Four samples were prepared with different moisture contents and furthermore spruce wood was used as a reference sample. Combustion device used was a stove with a fixed fire grate. Studied parameters were ambient temperature, temperature of flue gases, coefficient of excess air, and contents of oxygen and carbon monoxide in flue gases. Laboratory measurement was performed on an analyser of flue gases whose function is based on electro-chemical converters. Measured values were first converted to a referential oxygen content in flue gases. Evaluation of these values was then made by regression analyses. The course of combustion process and its quality can be seen well in functional dependence of carbon monoxide on excess air coefficient. The area of combustion was the smallest with the least moist sample (3.2%) and increases with increasing moisture.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GB - Zemědělské stroje a stavby
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Agronomy Research
ISSN
1406-894X
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
8
Strana od-do
725-732
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—