Dry sorption stabilization of flue gases in biological waste incinerating facility with heating power under 5 MW
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41310%2F17%3A73645" target="_blank" >RIV/60460709:41310/17:73645 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Dry sorption stabilization of flue gases in biological waste incinerating facility with heating power under 5 MW
Popis výsledku v původním jazyce
Biological and medical waste is always classified as hazardous material such as it must be treated according to its hazardous characteristics. One of the best methods for disposal seems to be a thermal degradation. This research examines the effect of finely crushed sorbent Ca(OH)2 and NaHCO3 to eliminate these hazardous substances in a small incinerating facility with heating power under 5 MW. The experiment took place in an existing incinerating plant with capacity 250 kg h-1. Sorbents were injected into a flue gas flow at two different places. It was observed that the temperature of flue gas and the residence time significantly influence the sorbent refining effect that is caused by quantity of collision in flue gas stream. Sorbents were dosed into a system with a theoretical consumption excess to serve sufficient refining effect. At dosing rate of 7 kg h-1 Ca(OH)2 the concentration of SO2 decreased by 34,5% and HCl by 59,0% referring to the initial concentration. At dosing rate of 5 kg h-1 NaHCO3
Název v anglickém jazyce
Dry sorption stabilization of flue gases in biological waste incinerating facility with heating power under 5 MW
Popis výsledku anglicky
Biological and medical waste is always classified as hazardous material such as it must be treated according to its hazardous characteristics. One of the best methods for disposal seems to be a thermal degradation. This research examines the effect of finely crushed sorbent Ca(OH)2 and NaHCO3 to eliminate these hazardous substances in a small incinerating facility with heating power under 5 MW. The experiment took place in an existing incinerating plant with capacity 250 kg h-1. Sorbents were injected into a flue gas flow at two different places. It was observed that the temperature of flue gas and the residence time significantly influence the sorbent refining effect that is caused by quantity of collision in flue gas stream. Sorbents were dosed into a system with a theoretical consumption excess to serve sufficient refining effect. At dosing rate of 7 kg h-1 Ca(OH)2 the concentration of SO2 decreased by 34,5% and HCl by 59,0% referring to the initial concentration. At dosing rate of 5 kg h-1 NaHCO3
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20302 - Applied mechanics
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Agronomy Research
ISSN
1406-894X
e-ISSN
—
Svazek periodika
15
Číslo periodika v rámci svazku
Special Issue 1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
9
Strana od-do
1024-1032
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85019640658