Balancers of various constructions are currently used for the operation control of the batteries connected in series. Unidirectional balancers ensure proper charging of all battery cells in a way that the first loaded cells should not be overcharged. Active balancers distribute the power, supplied to already-charged cells, to other cells, the power is further consumed by the passive balancers. Bidirectional balancers enable distributing the power between the cells during the discharge process, as well. This process thus protects the fastest discharging cells against the deep discharge. Passive balancers are most often used in batteries charged by the currents up to 20 A. If there are not big differences between individual cells in the battery, passive balancers reduce the efficiency of the charging process by only a few percent. They are the cheapest and most reliable. Optimally adjusted balancers with very low internal resistance deteriorate the efficiency only by about 1 percent. Commercially avail
Název v anglickém jazyce
Optimization of the balancer for LiFePO4 battery charging
Popis výsledku anglicky
Balancers of various constructions are currently used for the operation control of the batteries connected in series. Unidirectional balancers ensure proper charging of all battery cells in a way that the first loaded cells should not be overcharged. Active balancers distribute the power, supplied to already-charged cells, to other cells, the power is further consumed by the passive balancers. Bidirectional balancers enable distributing the power between the cells during the discharge process, as well. This process thus protects the fastest discharging cells against the deep discharge. Passive balancers are most often used in batteries charged by the currents up to 20 A. If there are not big differences between individual cells in the battery, passive balancers reduce the efficiency of the charging process by only a few percent. They are the cheapest and most reliable. Optimally adjusted balancers with very low internal resistance deteriorate the efficiency only by about 1 percent. Commercially avail
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Agronomy Research
ISSN
1406-894X
e-ISSN
—
Svazek periodika
15
Číslo periodika v rámci svazku
Special Issue 1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
11
Strana od-do
1141-1151
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85019577910