Influence of moisture on thermal properties of walls in basements of buildings
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41310%2F17%3A74750" target="_blank" >RIV/60460709:41310/17:74750 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.22616/ERDev2017.16.N096" target="_blank" >http://dx.doi.org/10.22616/ERDev2017.16.N096</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.22616/ERDev2017.16.N096" target="_blank" >10.22616/ERDev2017.16.N096</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of moisture on thermal properties of walls in basements of buildings
Popis výsledku v původním jazyce
The aim of this paper is to present the results of evaluation of the main thermal-heat properties in basement rooms with partly wet and partly dry peripheral wall. The surface temperature and surface moisture were determined by measurement in wet and dry parts of the wall in the same room. The moisture of the wet part was approximately four times higher than of the dry part of the wall. The heat flux density passing from the heated room through the wall was also measured using a special sensor. The measurement results showed a significant effect of high wall moisture on the heat losses, as the heat flux density was one and a half times higher. The obtained results from this measurement and findings may be useful for further research in this issue as well as for practical solutions for similar problems in many older buildings.
Název v anglickém jazyce
Influence of moisture on thermal properties of walls in basements of buildings
Popis výsledku anglicky
The aim of this paper is to present the results of evaluation of the main thermal-heat properties in basement rooms with partly wet and partly dry peripheral wall. The surface temperature and surface moisture were determined by measurement in wet and dry parts of the wall in the same room. The moisture of the wet part was approximately four times higher than of the dry part of the wall. The heat flux density passing from the heated room through the wall was also measured using a special sensor. The measurement results showed a significant effect of high wall moisture on the heat losses, as the heat flux density was one and a half times higher. The obtained results from this measurement and findings may be useful for further research in this issue as well as for practical solutions for similar problems in many older buildings.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
16th International Scientific Conference Engineering for Rural Development
ISBN
—
ISSN
1691-3043
e-ISSN
—
Počet stran výsledku
4
Strana od-do
492-495
Název nakladatele
Latvia University of Agriculture
Místo vydání
Jelgava; Latvia
Místo konání akce
Jelgava; Latvia
Datum konání akce
24. 5. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000416378300073