Influence of glass fibre fabrics/epoxy hybrid adhesive layer on mechanical properties of adhesive bond
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41310%2F19%3A79479" target="_blank" >RIV/60460709:41310/19:79479 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/978-3-319-91334-6_75" target="_blank" >http://dx.doi.org/10.1007/978-3-319-91334-6_75</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-3-319-91334-6_75" target="_blank" >10.1007/978-3-319-91334-6_75</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of glass fibre fabrics/epoxy hybrid adhesive layer on mechanical properties of adhesive bond
Popis výsledku v původním jazyce
An experimental program describes mechanical properties of hybrid adhesive bonds created with a two-component structural adhesive and a reinforcing glass fibre fabric (GF) tested at 20, 40 and 60C. The reinforcing fabric was of a type E glass fibres which was implemented into the adhesive bonds without a treatment and with a plasma treatment with a power of 175 W and 350 W. The adhesive bonds without the reinforcing GF showed at the temperature 20C a shear tensile strength 11,51 MPa. This shear tensile strength was considerably decreased with increasing temperature. The hybrid adhesive bonds with the reinforcing GF of weights in grams 110 and 160 g/m2 showed a significant increase of the shear tensile strength, namely up of ca. 63%. An influence of the plasma treatment was not significant. The significant increase of the shear tensile strength was reached by adding the reinforcing fabric. Higher values of the shear tensile strength were reached at the hybrid adhesive bonds reinforced with the GF of t
Název v anglickém jazyce
Influence of glass fibre fabrics/epoxy hybrid adhesive layer on mechanical properties of adhesive bond
Popis výsledku anglicky
An experimental program describes mechanical properties of hybrid adhesive bonds created with a two-component structural adhesive and a reinforcing glass fibre fabric (GF) tested at 20, 40 and 60C. The reinforcing fabric was of a type E glass fibres which was implemented into the adhesive bonds without a treatment and with a plasma treatment with a power of 175 W and 350 W. The adhesive bonds without the reinforcing GF showed at the temperature 20C a shear tensile strength 11,51 MPa. This shear tensile strength was considerably decreased with increasing temperature. The hybrid adhesive bonds with the reinforcing GF of weights in grams 110 and 160 g/m2 showed a significant increase of the shear tensile strength, namely up of ca. 63%. An influence of the plasma treatment was not significant. The significant increase of the shear tensile strength was reached by adding the reinforcing fabric. Higher values of the shear tensile strength were reached at the hybrid adhesive bonds reinforced with the GF of t
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20505 - Composites (including laminates, reinforced plastics, cermets, combined natural and synthetic fibre fabrics; filled composites)
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Lecture Notes in Electrical Engineering, 3rd Conference on Innovation, Engineering and Entrepreneurship
ISBN
978-331991333-9
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
554-560
Název nakladatele
Springer Verlag
Místo vydání
Guimaraes; Portugal
Místo konání akce
Guimaraes; Portugal
Datum konání akce
27. 6. 2018