Popis výsledku v původním jazyce
While the existing research provides a wealth of information about the static properties of RTK receivers, less is known about their dynamic properties, although it is clear that the vast majority of field operations take place when the machine is moving. A new method using a MRA for the evaluation of RTK receivers in movement with a precise circular reference trajectory (r = 3 m) was proposed. This reference method was developed with the greatest possible emphasis on the positional, time and repeatable accuracy of ground truth. Four phases of the measurement scenario (static, acceleration, uniform movement and deceleration) were used in order to compare four different types of RTK receiver horizontal operation accuracy over three measurement days. The median values of the deviations were always better during uniform movements than during acceleration or braking. In general, the positioning accuracy was worse in the dynamic mode than in the static one for all the receivers. Error indicators (RMSerr a
Název v anglickém jazyce
Comparison of Four RTK Receivers Operating in the Static and Dynamic Modes Using Measurement Robotic Arm
Popis výsledku anglicky
While the existing research provides a wealth of information about the static properties of RTK receivers, less is known about their dynamic properties, although it is clear that the vast majority of field operations take place when the machine is moving. A new method using a MRA for the evaluation of RTK receivers in movement with a precise circular reference trajectory (r = 3 m) was proposed. This reference method was developed with the greatest possible emphasis on the positional, time and repeatable accuracy of ground truth. Four phases of the measurement scenario (static, acceleration, uniform movement and deceleration) were used in order to compare four different types of RTK receiver horizontal operation accuracy over three measurement days. The median values of the deviations were always better during uniform movements than during acceleration or braking. In general, the positioning accuracy was worse in the dynamic mode than in the static one for all the receivers. Error indicators (RMSerr a
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
21100 - Other engineering and technologies
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
SENSORS
ISSN
1424-8220
e-ISSN
—
Svazek periodika
21
Číslo periodika v rámci svazku
23
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
24
Strana od-do
0-0
Kód UT WoS článku
000734562300001
EID výsledku v databázi Scopus
—