Korozní testování Mg anod
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41310%2F25%3A106125" target="_blank" >RIV/60460709:41310/25:106125 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
čeština
Název v původním jazyce
Korozní testování Mg anod
Popis výsledku v původním jazyce
This report presents an evaluation of the corrosion behaviour of three sets of magnesium (Mg) anodes (Sets 1–3) supplied by VAV Elektronic, s.r.o. The corrosion performance was assessed using a combination of electrochemical methods—specifically potentiodynamic polarisation (Tafel analysis)—and gravimetric mass-loss measurements in a 3 wt.% NaCl solution at laboratory temperature. The electrochemical tests enabled determination of corrosion rates, corrosion currents, current densities, and polarisation resistance for individual samples. The obtained values are consistent with the typical corrosion behaviour of magnesium in chloride-containing environments and do not indicate statistically significant differences among the tested anode sets. Gravimetric measurements performed after exposure periods of 24 and 168 hours revealed no measurable mass loss for any of the samples. Based on the results of both analytical approaches, no clear distinction between the best or worst corrosion performance among the three anode sets could be established, as all samples exhibited comparable and stable corrosion characteristics.
Název v anglickém jazyce
Mg Anodes Corrosion Testing
Popis výsledku anglicky
This report presents an evaluation of the corrosion behaviour of three sets of magnesium (Mg) anodes (Sets 1–3) supplied by VAV Elektronic, s.r.o. The corrosion performance was assessed using a combination of electrochemical methods—specifically potentiodynamic polarisation (Tafel analysis)—and gravimetric mass-loss measurements in a 3 wt.% NaCl solution at laboratory temperature. The electrochemical tests enabled determination of corrosion rates, corrosion currents, current densities, and polarisation resistance for individual samples. The obtained values are consistent with the typical corrosion behaviour of magnesium in chloride-containing environments and do not indicate statistically significant differences among the tested anode sets. Gravimetric measurements performed after exposure periods of 24 and 168 hours revealed no measurable mass loss for any of the samples. Based on the results of both analytical approaches, no clear distinction between the best or worst corrosion performance among the three anode sets could be established, as all samples exhibited comparable and stable corrosion characteristics.
Klasifikace
Druh
V<sub>utaj</sub> - Výzkumná zpráva obsahující utajované informace
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
U - Předmět řešení projektu je utajovanou skutečností podle zvláštních právních předpisů nebo je skutečností, jejíž zveřejnění by mohlo ohrozit činnost zpravodajské služby. Údaje o projektu jsou upraveny tak, aby byly zveřejnitelné
Údaje specifické pro druh výsledku
Počet stran výsledku
5
Místo vydání
Praha
Název nakladatele resp. objednatele
VAV Elektronic, s.r.o.
Verze
—