Influence of Temperature on the Strength of Bonded Joints
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41320%2F15%3A67509" target="_blank" >RIV/60460709:41320/15:67509 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.15376/biores.10.3.3999-4010" target="_blank" >http://dx.doi.org/10.15376/biores.10.3.3999-4010</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.15376/biores.10.3.3999-4010" target="_blank" >10.15376/biores.10.3.3999-4010</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of Temperature on the Strength of Bonded Joints
Popis výsledku v původním jazyce
The objective of this study was to assess the influence of varying temperature on the strength characteristics of joints bonded using three types of one-component PVAc adhesives (i.e., Rakoll Express D3, Titebond II Premium, and Rhenocoll 3W, 4B Plus) that belong to the group of thermoplastic wood adhesives intended for non-construction bonding applications. The measuring procedure was a transverse tensile test for estimation of joint strength. As documented by the test results, a higher joint strengthachieved at a higher temperature was achieved again after a gradual increase in the joint temperature from 20 °C to 140 °C and subsequent cooling to the starting temperature. After cooling the joint to the starting temperature, all tested adhesives complied with the minimum strength, namely 10 MPa. The results obtained in this study indicated that the resistance and thus the strength of joints bonded using contemporary PVAc adhesives increases with time.
Název v anglickém jazyce
Influence of Temperature on the Strength of Bonded Joints
Popis výsledku anglicky
The objective of this study was to assess the influence of varying temperature on the strength characteristics of joints bonded using three types of one-component PVAc adhesives (i.e., Rakoll Express D3, Titebond II Premium, and Rhenocoll 3W, 4B Plus) that belong to the group of thermoplastic wood adhesives intended for non-construction bonding applications. The measuring procedure was a transverse tensile test for estimation of joint strength. As documented by the test results, a higher joint strengthachieved at a higher temperature was achieved again after a gradual increase in the joint temperature from 20 °C to 140 °C and subsequent cooling to the starting temperature. After cooling the joint to the starting temperature, all tested adhesives complied with the minimum strength, namely 10 MPa. The results obtained in this study indicated that the resistance and thus the strength of joints bonded using contemporary PVAc adhesives increases with time.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JP - Průmyslové procesy a zpracování
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
BioResources
ISSN
1930-2126
e-ISSN
—
Svazek periodika
10
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
12
Strana od-do
3999-4010
Kód UT WoS článku
000364199800017
EID výsledku v databázi Scopus
—