Styrene Degradation Along the Bed Height of Perlite Biofilter
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22310%2F01%3A00004636" target="_blank" >RIV/60461373:22310/01:00004636 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60461373:22320/01:00004636 RIV/60461373:22330/01:00004636
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Styrene Degradation Along the Bed Height of Perlite Biofilter
Popis výsledku v původním jazyce
The whole bed height of biofilter was divided into four individual reactor stages in series. This configuration permits a measurement of the leachate pH of each stage individually and minimise interstage mixing of the immobilized culture.The extent to which the residence time of pollutant in the filter bed influenced biodegradation characteristics and the composition of immobilized culture under conditions of the constant loading rate was studied using a perlite biofilter having an internal diameter of50 mm and the bed height of each stage 27 cm. The residence time of pollutant in the bed had no influence on the removal efficiency and the elimination capacity regarding to the whole biofilter although some changes of these parameters in the individualstages were observed.The biofilter achieved an elimination capacity of 140 g.m-3.h-1 at removal efficiencies greater than 90%. Degradation activity decreased the pH value of leachate to 3.5 - 3.0. Microbial analyses showed that styrene wa
Název v anglickém jazyce
Styrene Degradation Along the Bed Height of Perlite Biofilter
Popis výsledku anglicky
The whole bed height of biofilter was divided into four individual reactor stages in series. This configuration permits a measurement of the leachate pH of each stage individually and minimise interstage mixing of the immobilized culture.The extent to which the residence time of pollutant in the filter bed influenced biodegradation characteristics and the composition of immobilized culture under conditions of the constant loading rate was studied using a perlite biofilter having an internal diameter of50 mm and the bed height of each stage 27 cm. The residence time of pollutant in the bed had no influence on the removal efficiency and the elimination capacity regarding to the whole biofilter although some changes of these parameters in the individualstages were observed.The biofilter achieved an elimination capacity of 140 g.m-3.h-1 at removal efficiencies greater than 90%. Degradation activity decreased the pH value of leachate to 3.5 - 3.0. Microbial analyses showed that styrene wa
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EI - Biotechnologie a bionika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA104%2F99%2F1623" target="_blank" >GA104/99/1623: Degradace xylenu, toluenu, styrenu, benzinových par a acetonu v odpadních plynech</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2001
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chemical Technology and Biotechnology
ISSN
0268-2575
e-ISSN
—
Svazek periodika
76
Číslo periodika v rámci svazku
76
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
873-878
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—