Study of mass transfer in a vertically moving particle bed electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22310%2F03%3A00007898" target="_blank" >RIV/60461373:22310/03:00007898 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60461373:22340/03:00007898
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Study of mass transfer in a vertically moving particle bed electrode
Popis výsledku v původním jazyce
A study was made of the influence of process parameters on the mass-transfer coefficient in a flow-through cell with a cascade of rotating drums partially filled with conductive particles ( called the 'vertically moving particle bed'). Copper depositionfrom an acidic sodium sulphate solution was used as the model reaction. To evaluate the experimental data a macrohomogeneous mathematical model of potential and current density distribution inside the cell was developed. The electrolyte flow distributionbetween the empty space above the particle bed and through the bed was evaluated. On the basis of these results the following correlation is proposed: Sh = 1.09/epsilon Re-p(1/3) Sc-1/3 + 52.8 Re-r/ 2498 + Re-r {1 - exp [-125(1.04 x 10(-6)Re(r) + Re-p) ]}. where the first term corresponds to the packed bed electrode and the second term represents the contribution of bed rotation. It is valid for bed porosity of 45%, cathode drum rotation rates between 0.047 and 0.120 Hz (i.e., 2.8 to 7.2
Název v anglickém jazyce
Study of mass transfer in a vertically moving particle bed electrode
Popis výsledku anglicky
A study was made of the influence of process parameters on the mass-transfer coefficient in a flow-through cell with a cascade of rotating drums partially filled with conductive particles ( called the 'vertically moving particle bed'). Copper depositionfrom an acidic sodium sulphate solution was used as the model reaction. To evaluate the experimental data a macrohomogeneous mathematical model of potential and current density distribution inside the cell was developed. The electrolyte flow distributionbetween the empty space above the particle bed and through the bed was evaluated. On the basis of these results the following correlation is proposed: Sh = 1.09/epsilon Re-p(1/3) Sc-1/3 + 52.8 Re-r/ 2498 + Re-r {1 - exp [-125(1.04 x 10(-6)Re(r) + Re-p) ]}. where the first term corresponds to the packed bed electrode and the second term represents the contribution of bed rotation. It is valid for bed porosity of 45%, cathode drum rotation rates between 0.047 and 0.120 Hz (i.e., 2.8 to 7.2
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA104%2F99%2F0433" target="_blank" >GA104/99/0433: Elektrochemická redukce dusičnanových iontů v roztocích používaných při regeneraci iontově výměnných kolon v úpravnách pitných a technologických vod</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Applied Electrochemistry
ISSN
0021-891X
e-ISSN
—
Svazek periodika
33
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
205-213
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—