Are calculated enthalpies of formation sometimes more reliable than experimental? A test on alkyl substituted benzoic acids
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22310%2F06%3A00017572" target="_blank" >RIV/60461373:22310/06:00017572 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388963:_____/06:00041087
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Are calculated enthalpies of formation sometimes more reliable than experimental? A test on alkyl substituted benzoic acids
Popis výsledku v původním jazyce
Energies of 20 alkyl-substituted benzoic acids were calculated at the levels B3LYP/6-311+G(d,p)//B3LYP/6-311+G(d,p) and MP2/6-311+G(d,p)//MP2/6-311+G(d,p); the pertinent enthalpies at 298 K were calculated at the same levels. Comparison with experimentalenthalpies of formation fH°g(298) was carried out in terms of isodesmic reactions, that is, in the relative values. Of the four calculated quantities, the DFT enthalpies yielded best correlation with the standard deviation of 2.1 kJ mol-1, near to the experimental uncertainty; the DFT energies are only slightly worse and the MP2 enthalpies or energies much worse. However, the DFT method overestimated systematically the substituent effects and had to be calibrated. Comparison with the experimental gas-phase acidities was less telling and the fit was worse because both methods overestimated the substituent effects. Extending the base in selected examples did not give better results. Although the systematic deviations are evidently due to
Název v anglickém jazyce
Are calculated enthalpies of formation sometimes more reliable than experimental? A test on alkyl substituted benzoic acids
Popis výsledku anglicky
Energies of 20 alkyl-substituted benzoic acids were calculated at the levels B3LYP/6-311+G(d,p)//B3LYP/6-311+G(d,p) and MP2/6-311+G(d,p)//MP2/6-311+G(d,p); the pertinent enthalpies at 298 K were calculated at the same levels. Comparison with experimentalenthalpies of formation fH°g(298) was carried out in terms of isodesmic reactions, that is, in the relative values. Of the four calculated quantities, the DFT enthalpies yielded best correlation with the standard deviation of 2.1 kJ mol-1, near to the experimental uncertainty; the DFT energies are only slightly worse and the MP2 enthalpies or energies much worse. However, the DFT method overestimated systematically the substituent effects and had to be calibrated. Comparison with the experimental gas-phase acidities was less telling and the fit was worse because both methods overestimated the substituent effects. Extending the base in selected examples did not give better results. Although the systematic deviations are evidently due to
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CC - Organická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal Comput.Chem.
ISSN
0192-8651
e-ISSN
—
Svazek periodika
27
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
571-577
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—