Critical assessment of suitable methods used for determination of antibacterial properties at photocatalytic surfaces
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22310%2F11%3A43892491" target="_blank" >RIV/60461373:22310/11:43892491 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60461373:22320/11:43892491
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.jhazmat.2011.08.009" target="_blank" >http://dx.doi.org/10.1016/j.jhazmat.2011.08.009</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jhazmat.2011.08.009" target="_blank" >10.1016/j.jhazmat.2011.08.009</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Critical assessment of suitable methods used for determination of antibacterial properties at photocatalytic surfaces
Popis výsledku v původním jazyce
This work describes the development of methods necessary for antibacterial effect evaluation on irradiated TiO2 layers. Two methods using bacteria suspensions and the glass adhesion method (based on ISO 27447:2009(E)) were critically assessed and compared. As test bacteria gram negative Escherichia coli and gram positive Enterococcus faecalis were employed. The method using 50cm3 of bacteria suspension is convenient for testing layers with strong antibacterial effect (prepared from powder photocatalysts). For the evaluation of the antibacterial effect of sol gel layers, the glass adhesion method based on the ISO is more appropriate than the method with 3cm3 of bacteria suspension. The reason is that the later does not allow a distinction between the inhibition effect of TiO2 and UV light itself. Some improvements of the ISO method were suggested, namely the use of gelatinous pills (CCM) of bacteria, using saline solution instead of nutrient broth for bacteria suspension preparation and
Název v anglickém jazyce
Critical assessment of suitable methods used for determination of antibacterial properties at photocatalytic surfaces
Popis výsledku anglicky
This work describes the development of methods necessary for antibacterial effect evaluation on irradiated TiO2 layers. Two methods using bacteria suspensions and the glass adhesion method (based on ISO 27447:2009(E)) were critically assessed and compared. As test bacteria gram negative Escherichia coli and gram positive Enterococcus faecalis were employed. The method using 50cm3 of bacteria suspension is convenient for testing layers with strong antibacterial effect (prepared from powder photocatalysts). For the evaluation of the antibacterial effect of sol gel layers, the glass adhesion method based on the ISO is more appropriate than the method with 3cm3 of bacteria suspension. The reason is that the later does not allow a distinction between the inhibition effect of TiO2 and UV light itself. Some improvements of the ISO method were suggested, namely the use of gelatinous pills (CCM) of bacteria, using saline solution instead of nutrient broth for bacteria suspension preparation and
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EE - Mikrobiologie, virologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Hazardous Materials
ISSN
0304-3894
e-ISSN
—
Svazek periodika
195
Číslo periodika v rámci svazku
—
Stát vydavatele periodika
BE - Belgické království
Počet stran výsledku
7
Strana od-do
100-106
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—