Influence of model organic air polutants on the fuel cell type PEM
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22310%2F12%3A43894360" target="_blank" >RIV/60461373:22310/12:43894360 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of model organic air polutants on the fuel cell type PEM
Popis výsledku v původním jazyce
The impact of air contained organic pollutants on platinum catalyst and unprotected fuel cell was investigated using linear voltammetry and fuel cell performance tests. The state of fuel cell was detected by using electrochemical impedance spectroscopy.Influence of different organic pollutant on the platinum catalyst was detected. Different way of catalyst regeneration was investigated and the best way was studied in detail. Results was verified in laboratory fuel cell. Volt pulse regeneration get thebest results, but this way can be potentially dangerous for catalyst support. Water in fuel cell is electrolyzed by volt pulse and generated oxygen oxidized organic pollutant. Unfortunately oxygen oxidized catalyst support too by long time pulses. Therefore only limited numbers of catalyst regenerations can be done.
Název v anglickém jazyce
Influence of model organic air polutants on the fuel cell type PEM
Popis výsledku anglicky
The impact of air contained organic pollutants on platinum catalyst and unprotected fuel cell was investigated using linear voltammetry and fuel cell performance tests. The state of fuel cell was detected by using electrochemical impedance spectroscopy.Influence of different organic pollutant on the platinum catalyst was detected. Different way of catalyst regeneration was investigated and the best way was studied in detail. Results was verified in laboratory fuel cell. Volt pulse regeneration get thebest results, but this way can be potentially dangerous for catalyst support. Water in fuel cell is electrolyzed by volt pulse and generated oxygen oxidized organic pollutant. Unfortunately oxygen oxidized catalyst support too by long time pulses. Therefore only limited numbers of catalyst regenerations can be done.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
New trends in application of photo and electro catalysis
ISBN
978-80-7080-809-2
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
103-106
Název nakladatele
VŠCHT Praha
Místo vydání
Praha
Místo konání akce
Hnanice, Czech republic
Datum konání akce
5. 12. 2011
Typ akce podle státní příslušnosti
EUR - Evropská akce